      An analytical and Monte Carlo investigation of the sufficiency of the present shielding of PET/CT imaging system at Tehran's Shariati hospital‎

      (ندگان)پدیدآور
      Gholami, ‎FereshtehAlibeigi, ‎EhsanShamsaei-Zafarghandi, ‎MojtabaNazemi, ‎Ehsan
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      637.7کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      ‎By the rapid development of imaging systems such as PET/CT for diagnosis of cancer‎, ‎the protection of staff and public has become a main health concern‎. ‎Due to serious and irreversible harms of ionization radiations‎, ‎protection of all those who are exposed is the main concern of health issues‎. ‎The main basis of the calculation of the shielding design in the medical imaging systems is that the absorbed dose should not exceed the allowed limit‎. ‎In this study‎, ‎the current shielding status of the PET/CT installations in Tehran's Shariati hospital was investigated using the MCNPX Monte Carlo code to ensure that the dose limits for both the controlled and uncontrolled area are not violated‎. ‎The proposed simulation method was benchmarked with a validated analytical method‎. ‎Shariati hospital provides services to four patients every day‎, ‎leading to a dose rate in the range of 2.6 × 10-6 to 9.35 × 10-3 mSv/week‎. ‎The minimum dose rate in this range represents the value behind the door of the waiting room (public uncontrolled area)‎, ‎while the maximum in this range corresponds to the value behind the glass of the scanner room (operator controlled area)‎. ‎The simulation results for 8 patients/day in this center showed that the dose rate behind the wall of the injection room will increase from 4.88 ×10-6 mSv/week to 2.81 × 10-2 mSv/week‎, ‎which is well below the recommended levels‎. ‎This indicates that the present shielding is adequate for up to four more patients per day‎.
      کلید واژگان
      ‎Positron-emission-tomography
      ‎Computed-tomography shielding
      ‎Dose rate
      ‎Monte Carlo Method
      ‎Analytical method‎

      شماره نشریه
      3
      تاریخ نشر
      2020-08-01
      1399-05-11
      ناشر
      K. N. Toosi University of Technology
      سازمان پدید آورنده
      Faculty of Nuclear Engineering and Physics‎, ‎Amirkabir University of Technology‎, ‎Tehran‎, ‎Iran‎.
      Faculty of Nuclear Engineering and Physics‎, ‎Amirkabir University of Technology‎, ‎Tehran‎, ‎Iran‎.
      Faculty of Nuclear Engineering and Physics‎, ‎Amirkabir University of Technology‎, ‎Tehran‎, ‎Iran‎.
      Nuclear Science and Technology Research Institute‎, ‎Tehran‎, ‎Iran

      شاپا
      2645-6397
      2645-5188
      URI
      https://dx.doi.org/10.22034/rpe.2020.89330
      http://rpe.kntu.ac.ir/article_89330.html
      https://iranjournals.nlai.ir/handle/123456789/41671

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب