• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Nursing and Midwifery Studies
    • Volume 3, Issue 3
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Nursing and Midwifery Studies
    • Volume 3, Issue 3
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    High-Flux and Low-Flux Membranes: Efficacy in Hemodialysis

    (ندگان)پدیدآور
    Oshvandi, KhodayarKavyannejad, RasolBorzuo, Sayed RezaGholyaf, Mahmoud
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    133.0کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background Inadequacy of dialysis is one of the main causes of death in hemodialysis patients. Some studies have suggested that high‐flux membrane improves the removal of moderate-sized molecules while other studies indicate no significant effect on them. Objectives This study aimed to investigate the dialysis efficacy of low-flux versus high-flux membranes in hemodialysis patients. Patients and Methods Forty hemodialysis patients participated in this cross-over clinical trial. Two sessions of low-flux and high-flux membrane dialysis were performed consecutively, in the first and second stage of the trial. In both stages, blood samples before and after the dialysis were taken and sent to the laboratory for assessment. Blood urea nitrogen (BUN), KT/V and the urea reduction ratio (URR) indexes were used to determine dialysis efficacy. Data were analyzed using t test and paired t test. Results The mean KT/V was 1.27 ± 0.28 in high-flux and 1.10 ± 0.32 in low-flux membrane which, these differences were statistically significant (P = 0.017). The mean of URR was 0.65 ± 0.09 in high-flux and 0.61 ± 0.14 in low-flux membrane, which these differences were not statistically significant (P = 0.221). Conclusions The high-flux membrane had better dialysis adequacy, so we suggest using high-flux membrane in hemodialysis centers.
    کلید واژگان
    Hemodialysis
    Dialysis Efficacy
    high
    Flux Membrane
    Low
    Iran

    شماره نشریه
    3
    تاریخ نشر
    2014-09-01
    1393-06-10
    ناشر
    Kashan University of Medical Sciences
    سازمان پدید آورنده
    1Research Center for Maternal and Child Care, Hamadan University of Medical Sciences, Hamadan, IR Iran
    2Nursing and Midwifery School, Hamadan University of Medical Sciences, Hamadan, IR Iran
    1Research Center for Maternal and Child Care, Hamadan University of Medical Sciences, Hamadan, IR Iran
    3Department of Nephrology, School of Medicine, Hamadan University of Medical Sciences, Hamadan, IR Iran

    شاپا
    2322-1488
    2322-1674
    URI
    https://dx.doi.org/10.17795/nmsjournal21764
    http://nmsjournal.kaums.ac.ir/article_65868.html
    https://iranjournals.nlai.ir/handle/123456789/41453

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب