    Investigation of the Effects of Link Beam Length on the RC Frame Retrofitted with the Linked Column Frame System

    (ندگان)پدیدآور
    Ezoddin, Alirezakheyroddin, A.Gholhaki, Majid
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    2.581 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Papers
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    This study investigates the effect of different link beam lengths in the Reinforced Concrete (RC) frame retrofitted with the Linked Column Frame (LCF) system. It also investigates the ratio of the link beam length (e) to the span length of the RC frame (L) from 0 to 1.5 for the 9 models of the RC frame retrofitted by the LCF system has been investigated. In addition, it studies the formation of plastic hinges in the RC and Linked Column (LC) frame, distribution of stiffness between the RC and LC frame and the ratio of the structural displacement with the formation of the first plastic hinge in the member of the RC frame at the collapse prevention level (Dp LCF) to the structural displacement with the formation of the first plastic hinge in the link beam (Dy LCF) has been studied. Based on the nonlinear static analysis results, the model with the ratio of e/L= 0.45 has a better performance than other different lengths of the link beam. In this model, the stiffness of the LC frame has increased about 78% in comparison with the model with the ratio of e/L that is more than 0.6. Also, the ratio of Dp LCF to Dy LCF for the model of e/L = 0.45 in comparison with two models of e/L = 0.3 and 0.6 is more about 14% and 22%, respectively. It means that, the model of e/L = 0.45 has more potential to reach the performance level of Rapid Repair (RR) to occupancy.
    کلید واژگان
    Link Beam
    Linked Column Frame System
    Nonlinear Static
    Plastic Hinge
    Retrofitting

    شماره نشریه
    1
    تاریخ نشر
    2020-06-01
    1399-03-12
    ناشر
    University of Tehran
    سازمان پدید آورنده
    Faculty of Civil Engineering, University of Semnan, Semnan, Iran.
    Civil Engineering Faculty, Semnan University
    semnan university

    شاپا
    2322-2093
    2423-6691
    URI
    https://dx.doi.org/10.22059/ceij.2019.280596.1580
    https://ceij.ut.ac.ir/article_76798.html
    https://iranjournals.nlai.ir/handle/123456789/411284

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب