    Reliability Analysis of Corroded Reinforced Concrete Beams Using Enhanced HL-RF Method

    (ندگان)پدیدآور
    Mohammadi Farsani, ArashKeshtegar, Behrooz
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    648.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Papers
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Steel corrosion of bars in concrete structures is a complex process which leads to the reduction of the cross-section bars and decreasing the resistance of the concrete and steel materials. In this study, reliability analysis of a reinforced concrete beam with corrosion defects under the distributed load was investigated using the enhanced Hasofer-Lind and Rackwitz-Fiessler (EHL-RF) method based on relaxed approach. Robustness of the EHL-RF algorithm was compared with the HL-RF using a complicated example. It was seen that the EHL-RF algorithm is more robust than the HL-RF method. Finally, the effects of corrosion time were investigated using the EHL-RF algorithm for a reinforced concrete beam based on flexural strength in the pitting and general corrosion. The model uncertainties were considered in the resistance and load terms of flexural strength limit state function. The results illustrated that increasing the corrosion time-period leads to increase in the failure probability of the corroded concrete beam.
    کلید واژگان
    Corrosion
    Enhanced HL-RF method
    Failure Probability
    Reliability analysis
    Reinforced concrete
    Reliability and Risk Analysis

    شماره نشریه
    2
    تاریخ نشر
    2015-12-01
    1394-09-10
    ناشر
    University of Tehran
    سازمان پدید آورنده
    Lecture, Department of Civil Engineering, Farsan Branch, Islamic Azad University, Farsan, Iran
    Assistant Professor, Department of Civil Engineering, University of Zabol, P.O.Box: 9861335-856, Zabol, Iran.

    شاپا
    2322-2093
    2423-6691
    URI
    https://dx.doi.org/10.7508/ceij.2015.02.006
    https://ceij.ut.ac.ir/article_55707.html
    https://iranjournals.nlai.ir/handle/123456789/411256

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب