• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Rehabilitation in Civil Engineering
      • Volume 8, Issue 4
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Rehabilitation in Civil Engineering
      • Volume 8, Issue 4
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Improved Seismic Performance of Chevron Brace Frames Using Multi-Pipe Yield Dampers

      (ندگان)پدیدآور
      Behzadfar, BehnamMaleki, AhmadLotfollahi Yaghin, Mohammad Ali
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.387 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Regular Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Spacious experimental and numerical investigation has been conducted by researchers to increase the ductility and energy dissipation of concentrically braced frames. One of the most widely used strategies for increasing ductility and energy dissiption, is the use of energy-absorbing systems. In this regard, the cyclic behavior of a chevron bracing frame system equipped with multi-pipe dampers (CBF-MPD) was investigated through finite element method. The purpose of this study was to evaluate and improve the behavior of the chevron brace frame using multi-pipe dampers. Three-dimensional models of the chevron brace frame were developed via nonlinear finite element method using ABAQUS software. Finite element models included the chevron brace frame and the chevron brace frame equipped with multi-pipe dampers. The chevron brace frame model was selected as the base model for comparing and evaluating the effects of multi-tube dampers. Finite element models were then analyzed under cyclic loading and nonlinear static methods. Validation of the results of the finite element method was performed against the test results. In parametric studies, the influence of the diameter parameter to the thickness (D/t) ratio of the pipe dampers was investigated. The results indicated that the shear capacity of the pipe damper has a significant influence on determining the bracing behavior. Also, the results show that the corresponding displacement with the maximum force in the CBF-MPD compared to the CBF, increased by an average of 2.72 equal. Also, the proper choice for the dimensions of the pipe dampers increased the ductility and energy absorption of the chevron brace frame.
      کلید واژگان
      Chevron brace frames (CBF)
      Multi-pipe dampers (MPD)
      Nonlinear finite element method
      energy absorption
      Cyclic behavior
      Structural Engineering

      شماره نشریه
      4
      تاریخ نشر
      2020-11-01
      1399-08-11
      ناشر
      Semnan University
      سازمان پدید آورنده
      Department of Civil Engineering, Maragheh Branch, Islamic Azad University, Maragheh, Iran
      Department of Civil Engineering, Maragheh Branch, Islamic Azad University, Maragheh, Iran
      Department of Civil Engineering, University of Tabriz, Tabriz, Iran

      شاپا
      2345-4415
      2345-4423
      URI
      https://dx.doi.org/10.22075/jrce.2020.19792.1383
      https://civiljournal.semnan.ac.ir/article_4569.html
      https://iranjournals.nlai.ir/handle/123456789/409400

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب