      Bridge Bed Strengthening, Disaster Prevention due to Scouring

      (ندگان)پدیدآور
      Fadam Marfavi, MajidBasirat, ShamsaSadeghi, Sadegh
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.283 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Regular Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      One of the most important factors in determining the depth of foundations in structures adjacent to the water flow is the scouring phenomenon; the scouring is a phenomenon caused by the interactions between water flow and erodible bed materials, which causes the removal of sediments where hydraulic structures are located, including bridge piers. Every year, a great number of bridges are damaged due to local scoring of their piers and foundations. In this paper, the geotechnical study of Malahide viaduct failure due to scouring was carried out using Plaxis 2D software. For this purpose, the Malahide viaduct, which was damaged in 2009 due to bed scouring of one of its piers, was selected and the necessary simulations were carried out based on the bridge specifications, and the conditions of the bridge underlying bed was investigated. Simulations results showed that the cause of scouring in the bed of collapsed pier was the high shear strains of the bed, bed shear strength parameters (i.e. angle of internal friction and cohesion) reduction and as a result, reducing the bed resistance to the scouring. It was also found that by using the micropile group below the foundation of bridge pier as a solution to reduce the scouring effect, the bed maximum scour depth is significantly reduced compared to the shallow foundations without micropiles; Also, by using the micropile group, the shallow foundation thickness can be reduced, provided that after foundation thickness reduction and micropiles application, the structure safety factor remains in the stable range.
      کلید واژگان
      Local Scour
      Bridge pier
      Malahide viaduct
      Shallow foundation
      Micropile
      Rehabilitation in Geotechnical Engineering

      شماره نشریه
      1
      تاریخ نشر
      2020-02-01
      1398-11-12
      ناشر
      Semnan University
      سازمان پدید آورنده
      Department of Civil Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran
      Department of Civil Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran
      Department of Civil Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran

      شاپا
      2345-4415
      2345-4423
      URI
      https://dx.doi.org/10.22075/jrce.2019.15637.1293
      https://civiljournal.semnan.ac.ir/article_3759.html
      https://iranjournals.nlai.ir/handle/123456789/409359

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب