    Bridge Bed Strengthening, Disaster Prevention due to Scouring

    (ندگان)پدیدآور
    Fadam Marfavi, MajidBasirat, ShamsaSadeghi, Sadegh
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.283 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Regular Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    One of the most important factors in determining the depth of foundations in structures adjacent to the water flow is the scouring phenomenon; the scouring is a phenomenon caused by the interactions between water flow and erodible bed materials, which causes the removal of sediments where hydraulic structures are located, including bridge piers. Every year, a great number of bridges are damaged due to local scoring of their piers and foundations. In this paper, the geotechnical study of Malahide viaduct failure due to scouring was carried out using Plaxis 2D software. For this purpose, the Malahide viaduct, which was damaged in 2009 due to bed scouring of one of its piers, was selected and the necessary simulations were carried out based on the bridge specifications, and the conditions of the bridge underlying bed was investigated. Simulations results showed that the cause of scouring in the bed of collapsed pier was the high shear strains of the bed, bed shear strength parameters (i.e. angle of internal friction and cohesion) reduction and as a result, reducing the bed resistance to the scouring. It was also found that by using the micropile group below the foundation of bridge pier as a solution to reduce the scouring effect, the bed maximum scour depth is significantly reduced compared to the shallow foundations without micropiles; Also, by using the micropile group, the shallow foundation thickness can be reduced, provided that after foundation thickness reduction and micropiles application, the structure safety factor remains in the stable range.
    کلید واژگان
    Local Scour
    Bridge pier
    Malahide viaduct
    Shallow foundation
    Micropile
    Rehabilitation in Geotechnical Engineering

    شماره نشریه
    1
    تاریخ نشر
    2020-02-01
    1398-11-12
    ناشر
    Semnan University
    سازمان پدید آورنده
    Department of Civil Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran
    Department of Civil Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran
    Department of Civil Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran

    شاپا
    2345-4415
    2345-4423
    URI
    https://dx.doi.org/10.22075/jrce.2019.15637.1293
    https://civiljournal.semnan.ac.ir/article_3759.html
    https://iranjournals.nlai.ir/handle/123456789/409359

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب