• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Rehabilitation in Civil Engineering
      • Volume 8, Issue 1
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Rehabilitation in Civil Engineering
      • Volume 8, Issue 1
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Seismic Behavior of Semi-Dry Precast Concrete Connections Using Tapered Thread Couplers

      (ندگان)پدیدآور
      Mobedi, EhsanParastesh, HosseinKhaloo, Alireza
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.361 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Regular Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      The worldwide use of precast concrete frames leads to an increase in the need for the investigation of efficient precast connections, particularly in the seismic regions. The current paper provides a numerical and experimental study on a dry precast connection. Experiments were conducted to validate the finite element method in the laboratory of the University of Science and Culture. To verify the validity of the result, the outcomes of the non-linear analysis of cross-shaped models were compared with the experimental results in terms of failure mode, ductility, lateral load-bearing capacity, and energy dissipation. The finite element non-linear analyses of the models represented an acceptable compatibility with experimental results. A parametric study has been carried out to survey the effect of the couplers and grout compressive strength on semi-dry connection behavior. Eventually, the response modification factors were determined for the case studies to demonstrate the seismic behavior in design forces. Statistical analysis of the numerical results demonstrates a 6 % increase for response modification factors of the specimens with the closest distance of couples to the column face in relation to those with the couplers farthest away from the column face. Eventually, it can be concluded that the specimens with a shorter coupler distance from the external face of the column and with a higher grout compressive strength lead to the appropriate results.
      کلید واژگان
      Dry Connection
      couplers array
      precast
      grout type
      seismic behavior
      Structural Engineering

      شماره نشریه
      1
      تاریخ نشر
      2020-02-01
      1398-11-12
      ناشر
      Semnan University
      سازمان پدید آورنده
      University of Science and Culture
      University of Science & Culture
      Department of Civil Engineering, Sharif University, Tehran, Iran

      شاپا
      2345-4415
      2345-4423
      URI
      https://dx.doi.org/10.22075/jrce.2019.16827.1315
      https://civiljournal.semnan.ac.ir/article_3758.html
      https://iranjournals.nlai.ir/handle/123456789/409356

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب