      Leak Detection in Water Collection and Transmission Networks Using the Minimum Nodal Pressure Measurement

      (ندگان)پدیدآور
      Asgari, Hamid RezaMaghrebi, Mahmoud F
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.256 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Regular Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Leak has always been one of the problems in water distribution networks, whose preventing not only results in the saving of water sources but also has profound effects on the maintenance cost of networks. In the present paper, a new method is applied for leak detection in water collection and transmission network. In this method, detection of leak location is performed by pressure difference analysis at junctions and by the help of the relative index of the leak. The pressure measurements should be performed at least at two nodes for two cases of with and without the presence of leak. The minimum number of pressure measurements to form a relative leak index is two. However, in this case, two nodal pressure measurements are too few, and the number of pressure measurement should be increased. Therefore the next option for the number of measurements is three. The investigated network in this research includes 7 wells with an approximate length of 7800 m located in the northwestern city of Mashhad. A real leak with a rate of 7.57 l/s is created at one of the network nodes whose amount is measurable by a volume counter. The real leak is a hypothetical leak which is known in advance, and its magnitude is not necessarily a round number in term of a liter per second. Finally, this leak is identified by the proposed method via 3 nodal pressure measurements.
      کلید واژگان
      Leak Detection
      Nodal Pressure
      Water Conveyance System
      Head Loss
      Leak Index
      Rehabilitation in Water Supply and Drainage Engineering

      شماره نشریه
      1
      تاریخ نشر
      2018-02-01
      1396-11-12
      ناشر
      Semnan University
      سازمان پدید آورنده
      Department of Civil Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
      Civil Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, P. O. Box 91755-1111, Mashhad, Iran.

      شاپا
      2345-4415
      2345-4423
      URI
      https://dx.doi.org/10.22075/jrce.2017.12353.1212
      https://civiljournal.semnan.ac.ir/article_2727.html
      https://iranjournals.nlai.ir/handle/123456789/409293

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب