• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Rehabilitation in Civil Engineering
      • Volume 1, Issue 2
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Rehabilitation in Civil Engineering
      • Volume 1, Issue 2
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Seismic Behavior Assessment of Concrete Elevated Water Tanks

      (ندگان)پدیدآور
      Bozorgmehrnia, S.Ranjbar, M.M.Madandoust, R.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1000.کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Elevated tanks are very important structures and consist of various types. Water supply is vital to control fires during earthquakes. Also they are utilized to store different products, like petroleum supplies in cities and industrial zones. Damage to these structures during strong ground motions may lead to fire or other hazardous events. Elevated tanks should stay functional after and before earthquakes. However their dynamic behavior differs greatly in comparison with other structures. In this research, a sample of reinforced concrete elevated water tank, with 900 cubic meters capacity, exposed to three pair of earthquake records have been studied and analyzed in time history using mechanical and finite-element modeling technique. The liquid mass of tank is modeled as lumped masses known as sloshing mass, or impulsive mass. The corresponding stiffness constants associated with these lumped masses have been worked out depending upon the properties of the tank wall and liquid mass. Tank responses including base shear, overturning moment, tank displacement, and sloshing displacement have been calculated. Results reveal that the system responses are highly influenced by the structural parameters and the earthquake characteristics such as frequency content.
      کلید واژگان
      Elevated Water Tank
      seismic behavior
      Ensemble earthquake records
      Base shear
      Overturning moment
      Sloshing displacement

      شماره نشریه
      2
      تاریخ نشر
      2013-08-01
      1392-05-10
      ناشر
      Semnan University
      سازمان پدید آورنده
      M.Sc., Civil Engineering Department, Guilan University, Rasht, Iran
      Ph.D., Civil Engineering Department, Guilan University, Rasht, Iran
      Ph.D., Civil Engineering Department, Guilan University, Rasht, Iran

      شاپا
      2345-4415
      2345-4423
      URI
      https://dx.doi.org/10.22075/jrce.2013.8
      https://civiljournal.semnan.ac.ir/article_8.html
      https://iranjournals.nlai.ir/handle/123456789/409232

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب