• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Dentistry
      • Volume 10, Issue 4
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Dentistry
      • Volume 10, Issue 4
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      The Effect of Different Light Curing Modes on Microleakage of Composite Restorations

      (ندگان)پدیدآور
      Nemati Anaraki, S.Hajighasemi, Y.
      Thumbnail
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Statement of problem: One of the major problems in composite restorations is polymerization shrinkage leading to microleakage, hypersensitivity, recurrent carries, pulpal inflammation, and later pulp necrosis. To overcome these problems, different photo-activation methods have been employed to prolong the plastic phase during polymerization.Purpose: To investigate the mircoleakage in 3 groups of Pulse, Ramp and conventional LED photo-polymerization methods in class V composite restorations.Materials and Method: Twenty one freshly extracted human premolars were categorized in 3 groups of 7 each. Slot shaped class V cavities (4 ´ 2 ´ 2 mm) were prepared on both buccal and lingual surfaces of the teeth, with occlusal margins on the enamel and gingival margins 1mm below the CEJ. The cavities were restored with single bond  and Z100  composite (3M ESPE,USA) and cured in group A with Ramp, group B with Pulse mode, and group C with Conventional mode using Apoza LED Turbo light Curing unit. After one day storage in 37°C water and thermo cycling for 1000 cycles, the teeth were sealed with nail varnish 1 mm short of margins, immersed in AgNo3 50% W and then developed  in solution. The specimens were cut and evaluated by Stereo microscope at 40 x  magnification. The results were statistically analyzed by kruskal- Wallis test.Results: None of the specimens revealed microleakage at the occlusal margins but 69.2% of the specimens in Ramp group, 76.9% in the Pulse group and 61.5% in the conventional group showed score 1 gingival microleakage. Also, 30.8% in the Ramp and Conventional and 23.1% in the Pulse group showed score 2 gingival microleakage. Analysis of the data among the 3 groups revealed no statistically significant differences. ( p = 0.640)Conclusion: Based on the limitations of this study:1- All of LED photoactivation modes using Apoza LED turbo unit prevent microleakage in the enamel margins.2- None of the photoactivation modes can prevent microleakage in the gingival margins completely.3- For Z100 (microhybrid composite), all of the 3 employed methods were equally effective in microleakage reductionKey words: Microleakage, Photo activation mode, Class V cavities, Composite

      شماره نشریه
      4
      تاریخ نشر
      2009-12-01
      1388-09-10
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      Dept. of Operative Dentistry, Dental Faculty, Tehran Azad University, Tehran, Iran
      Dentist

      شاپا
      2345-6485
      2345-6418
      URI
      https://dentjods.sums.ac.ir/article_41262.html
      https://iranjournals.nlai.ir/handle/123456789/401243

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب