• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Dentistry
      • Volume 12, Issue 2
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Dentistry
      • Volume 12, Issue 2
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Clinical Comparison of Root Length Measurements with Electronic Apex Locator and Conventional Radiography in Mandibular Deciduous Teeth

      (ندگان)پدیدآور
      Eskandarian, T.Sahebi, S.Amirabadi, F.Alipour, A.
      Thumbnail
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Statement of Problem: Success in pulpectomy of deciduous teeth greatly depends on the accuracy of root length measurements which have mostly been done radiographically. However, X-ray risks and patient cooperation have usually been a challenge for the clinicians.Purpose: The clinical comparison of root length measurements with electronic apex locator and conventional radiography in 4-6 year old children's mandibular deciduous teeth was the aim of the present study.Materials and Method: In the current clinical trial, 15 mandibular molars with 60 canals in 4-6 year old patients who had the treatment plan of pulpectomy were chosen. The measured root lengths with apex locator and parallel technique radiography were evaluated with the same reference point. Data were analyzed using simple linear regression, coefficient of correlation, coefficient of variability and also graphic Bland Altman Plot.Results: The accuracy of electronic apex locator measurements in ±0/5 from apical foramen was 85%. In all cases without considering pulp situation, the difference between the two techniques was not significant.Conclusion: The electronic apex locators are recommended for root length measurements of the deciduous mandibular molars without apical resorption, disregarding the pulp status, especially when initial radiographic films are available.Key words: Electronic apex locator, Mandibular deciduous teeth, Pulpectomy, Radiography

      شماره نشریه
      2
      تاریخ نشر
      2011-06-01
      1390-03-11
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      Dept. of Pediatric Dentistry, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
      Dept. of Endodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
      Dept. of Pediatric Dentistry, School of Dentistry, Zahedan University of Medical Sciences, Zahedan, Iran
      Dept. of Epidemiology, School of Health and Nutrition, Shiraz University of Medical Sciences, Shiraz, Iran

      شاپا
      2345-6485
      2345-6418
      URI
      https://dentjods.sums.ac.ir/article_41225.html
      https://iranjournals.nlai.ir/handle/123456789/400985

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب