    Comparison of Dimensional Accuracy of Two Acrylic Resins Polymerized by Injection Molding

    (ندگان)پدیدآور
    Vojdani, M.Joolayi, J.
    Thumbnail
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Statement of Problem: Despite the fact that polymethyl methacrylate is the most popular material in denture base construction, one of its main defects is the polymerization shrinkage that frequently leads in time consuming clinical problems. Several ways have been suggested to solve this problem; among them is "injection molding method".Purpose: The purpose of this study was the assessment of dimensional accuracy of the two acrylic resins cured by injection molding method.Materials and Method: In this experimental study, the dimensional accuracy of two acrylic resins after curing by injection molding method (Unipress system) was assessed by profile projector measurement. Twenty master casts were made of a master dye simulating both maxillary and mandibular edentulous arch. They were divided in two groups, each group containing 10 casts used for making denture bases. Three reference points were determined, one in the central incisor region and the other two symmetrical points in the posterior region in molar area. Three measurements were made: 1. on the master cast, 2. on the denture base just after removing the denture base from the master cast, and 3. after immersion in water for one week. The measurements were analyzed using Friedman and Mann-Whitney tests.     Results: All the denture bases in both groups, revealed significant shrinkage after removing from casts (p0.05) in any of the groups. Statistical analysis revealed no significant difference between the two acrylic resins too.Conclusion: Since there was no significant difference between dimensional accuracy of the two acrylic resins, it could be conclude that using Bayer acrylic resin with Unipress injection molding system would lead in acceptable results concerning dimensional accuracy. Key words: Dimensional accuracy, Injection molding, Acrylic resin

    شماره نشریه
    12
    تاریخ نشر
    2006-06-01
    1385-03-11
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Assistant Professor, Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences
    Prosthodontist

    شاپا
    2345-6485
    2345-6418
    URI
    https://dentjods.sums.ac.ir/article_41461.html
    https://iranjournals.nlai.ir/handle/123456789/400581

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب