• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Dentistry
    • Volume 8, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Dentistry
    • Volume 8, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effect of the Rest Seat Location Alteration on Distribution of Forces in the Distal Extended Abutment: A Finite Element Method Analysis

    (ندگان)پدیدآور
    Gharehchahe, J.Rostamkhani, F.Arbabi, R.Azari, A.
    Thumbnail
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Statement of problem: In designing extension type removable partial denture (R.P.D), there is lots of controversy regarding the suitable location of rest seat of the terminal abutment. Discussions and Controversies are, mostly focused on minimizing lateral stress placed on terminal abutments.Purpose: The purpose of this study was to assess the rate of stress placed on abutment teeth with different rest seat placements by a finite element method analysis.Materials and method: The skull of a 60 years old man was CT-Scanned with 0.5mm sections and data were used to make a 3.D model of the mandible. Then a partial denture was designed on this model, once with a distal rest on terminal abutment, and then with a mesial rest. Occlusal force was applied on the saddle, and stress was measured with a finite element method using "cosmos works 2003" soft ware.Results: In both conditions, the highest stress concentration was observed on the distal surfaces of the abutment teeth, and the lowest stress on buccal cusps and roots of the teeth. The rest seat itself was the only place in which the observed stress was different in two conditions. The distal rest seat received more stress than the mesial rest seat. In both conditions the underlying bone received a moderate amount of stress, increasing in the distal part.Conclusion: Displacing the rest did not alter the stress applied on the abutment teeth. So it may be claimed that this factor could be neglected when determining the place of terminal rest of extension type RPD.Key words: Rest seat, Free end, Finite element method analysis

    شماره نشریه
    1
    تاریخ نشر
    2007-03-01
    1385-12-10
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Associate Professor, Department of Porosthodontics, School of Dentistry, Mashhad University of Medical Sciences
    Associate Professor, Department of Porosthodontics, School of Dentistry, Mashhad University of Medical Sciences
    Assistant Professor, Department of Porosthodontics, School of Dentistry, Mashhad University of Medical Sciences
    Assistant Professor, Department of Porosthodontics, School of Dentistry, Mashhad University of Medical Sciences

    شاپا
    2345-6485
    2345-6418
    URI
    https://dentjods.sums.ac.ir/article_41435.html
    https://iranjournals.nlai.ir/handle/123456789/400554

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب