نمایش مختصر رکورد

dc.contributor.authorGhaemi, Arezooen_US
dc.contributor.authorSetareh, Zahraen_US
dc.date.accessioned1399-07-09T09:15:50Zfa_IR
dc.date.accessioned2020-09-30T09:15:50Z
dc.date.available1399-07-09T09:15:50Zfa_IR
dc.date.available2020-09-30T09:15:50Z
dc.date.issued2017-01-01en_US
dc.date.issued1395-10-12fa_IR
dc.date.submitted2016-12-31en_US
dc.date.submitted1395-10-11fa_IR
dc.identifier.citationGhaemi, Arezoo, Setareh, Zahra. (2017). New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions. Journal of Applied Chemical Research, 11(1), 81-94.en_US
dc.identifier.issn2008-3815
dc.identifier.issn2008-3823
dc.identifier.urihttp://jacr.kiau.ac.ir/article_527183.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/358156
dc.description.abstractA highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 mg. The sensor exhibits a nernstian slope (30.0±0.2 mV/ decade) in a wide linear concentration range of 1.0×10-5 to 1.0×10-1 M with detection limit of 8.7×10-6 M. The electrode has a fast response time of 15 s with a satisfactory reproducibility and relatively long life time of about 16 weeks without significant drift in potential. The sensor operates in the wide pH range of 2.0-10.0. This sensor reveals a good selectivity towards Cu2+ ion over a wide range of alkali, transition and heavy metal cations. The electrode was used as an indicator electrode for potentiometric titration of Cu2+ using EDTA solutions. The proposed sensor was applied for the direct determination of Cu2+ cation and the results were compared with those obtained from atomic absorption spectrometric analysis and were found in good agreement. Also this sensor was successfully used for determination of copper (II) in real samplesen_US
dc.format.extent2014
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherIslamic Azad University, Karaj branchen_US
dc.relation.ispartofJournal of Applied Chemical Researchen_US
dc.subjectCoated graphite sensoren_US
dc.subjectCopper (II) cationen_US
dc.subjectPotentiometryen_US
dc.subjectKryptofix 5en_US
dc.titleNew Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ionsen_US
dc.typeTexten_US
dc.typeResearch Paperen_US
dc.citation.volume11
dc.citation.issue1
dc.citation.spage81
dc.citation.epage94


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد