• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Applied Chemical Research
    • Volume 11, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Applied Chemical Research
    • Volume 11, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

    (ندگان)پدیدآور
    Ghaemi, ArezooSetareh, Zahra
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.967 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 mg. The sensor exhibits a nernstian slope (30.0±0.2 mV/ decade) in a wide linear concentration range of 1.0×10-5 to 1.0×10-1 M with detection limit of 8.7×10-6 M. The electrode has a fast response time of 15 s with a satisfactory reproducibility and relatively long life time of about 16 weeks without significant drift in potential. The sensor operates in the wide pH range of 2.0-10.0. This sensor reveals a good selectivity towards Cu2+ ion over a wide range of alkali, transition and heavy metal cations. The electrode was used as an indicator electrode for potentiometric titration of Cu2+ using EDTA solutions. The proposed sensor was applied for the direct determination of Cu2+ cation and the results were compared with those obtained from atomic absorption spectrometric analysis and were found in good agreement. Also this sensor was successfully used for determination of copper (II) in real samples
    کلید واژگان
    Coated graphite sensor
    Copper (II) cation
    Potentiometry
    Kryptofix 5

    شماره نشریه
    1
    تاریخ نشر
    2017-01-01
    1395-10-12
    ناشر
    Islamic Azad University, Karaj branch

    شاپا
    2008-3815
    2008-3823
    URI
    http://jacr.kiau.ac.ir/article_527183.html
    https://iranjournals.nlai.ir/handle/123456789/358156

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب