Diagnostic Performance of Whole-Body Diffusion-Weighted Imaging Compared to PET-CT Plus Brain MRI in Staging Clinically Resectable Lung Cancer
(ندگان)پدیدآور
Usuda, KatsuoMatoba, TakumaUsuda, KatsuoSagawa, MotoyasuMaeda, SumikoMotono, NozomuTanaka, MakotoMachida, YuichiroMunetaka Matoba, TakumaWatanabe, NaotoTonami, HisaoUeda, YoshimichiUramoto, Hidetakaنوع مدرک
TextSystematic Review and Meta-analysis
زبان مدرک
Englishچکیده
Background: Precise staging of lung cancer is usually evaluated by PET-CT and brain MRI. Recently, however, whole-body diffusion-weighted magnetic resonance imaging (WB-DWI) has be applied. The aim of this study is to determine whether the diagnostic performance of lung cancer staging by WB-DWI is superior to that of PET-CT+brain MRI.
Materials and Methods: PET-CT + brain MRI and WB-DWI were used for lung cancer staging before surgery with 59 adenocarcinomas, 16 squamous cell carcinomas and 6 other carcinomas.
Results: PET-CT + brain MRI correctly identified the pathologic N staging in 67 patients (82.7%), with overstaging in 5 (6.2%) and understaging in 9 (11.1%), giving a staging accuracy of 0.827. WB-DWI correctly identified the pathologic N staging in 72 patients (88.9%), with overstaging in 1 (1.2%) and understaging in 8 patients (9.9%), giving a staging accuracy of 0.889. There were no significant differences in accuracies. PET-CT + brain MRI correctly identified the pathologic stages in 56 patients (69.1%), with overstaging in 7 (8.6%) and understaging in 18 (22.2%), giving a staging accuracy of 0.691. WB-DWI correctly identified the pathologic stages in 61 patients (75.3%), with overstaging in 4 (4.9%) and understagings in16(19.7%), giving a staging accuracy of 0.753. There were no significant difference in accuracies.
Conclusions: Diagnostic efficacy of WB-DWI for lung cancer staging is equivalent to that of PET-CT + brain MRI.
کلید واژگان
Lung cancerstaging
whole body diffusion
weighted magnetic resonance imaging
MRI
PET-CT
شماره نشریه
6تاریخ نشر
2016-07-011395-04-11
ناشر
West Asia Organization for Cancer Prevention (WAOCP)سازمان پدید آورنده
Department of Thoracic Surgery, Kanazawa Medical University, Ishikawa, JapanDepartment of Thoracic Surgery, Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Thoracic Surgery, Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Thoracic Surgery, Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Thoracic Surgery, Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Thoracic Surgery, Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Thoracic Surgery, Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Radiology,Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Radiology,Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Radiology,Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Pathophysiological and Experimental Pathology, Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
Department of Thoracic Surgery, Kanazawa Medical University, Daigaku, Uchinada, Ishikawa, Japan
شاپا
1513-73682476-762X




