نمایش مختصر رکورد

dc.contributor.authorTavakkoli, Nahiden_US
dc.contributor.authorSoltani, Nasrinen_US
dc.contributor.authorAfsharpour, Arezoen_US
dc.date.accessioned1399-07-09T09:00:47Zfa_IR
dc.date.accessioned2020-09-30T09:00:47Z
dc.date.available1399-07-09T09:00:47Zfa_IR
dc.date.available2020-09-30T09:00:47Z
dc.date.issued2016-10-01en_US
dc.date.issued1395-07-10fa_IR
dc.date.submitted2015-07-27en_US
dc.date.submitted1394-05-05fa_IR
dc.identifier.citationTavakkoli, Nahid, Soltani, Nasrin, Afsharpour, Arezo. (2016). Determination of Captopril using platinum coated nanoporous gold film electrode. Quarterly Journal of Iranian Chemical Communication, 4(435949013), 414-432.en_US
dc.identifier.issn2423-4958
dc.identifier.issn2345-4806
dc.identifier.urihttp://icc.journals.pnu.ac.ir/article_2374.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/352969
dc.description.abstractIn this article electrochemical determination of captopril at the surface of the platinum coated nanoporous gold film (PtNPGF) electrode is reported using the cyclic voltammetry and amperometry. For the preparation of PtNPGF, the surface of NPGF electrode was covered with Cu layer using underpotential electrochemical deposition (UPD).Afterward, the copper layer is replaced with platinum ions via a spontaneous redox reaction to have a uniform Ptoverlayer. Under the optimized conditions, the amperometry peak current of captopril increased linearly with captopril concentration in the ranges of 4.70×10-8 to 4.57×10-5mol L−1. The detection limit of captopril was 1.2×10-8mol L−1. The results show a very good precision (R.S.D < 2.4%), suitable selectivity and very stable response for captopril. The proposed sensor was successfully applied for the determination of captopril in the urine samples of patient human.en_US
dc.format.extent802
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherIlam, Payame Noor Universityen_US
dc.relation.ispartofQuarterly Journal of Iranian Chemical Communicationen_US
dc.subjectNanoporousen_US
dc.subjectunder potential depositionen_US
dc.subjectplatinumen_US
dc.subjectCaptoprilen_US
dc.subjectAnalytical chemistryen_US
dc.titleDetermination of Captopril using platinum coated nanoporous gold film electrodeen_US
dc.typeTexten_US
dc.typeOriginal Research Articleen_US
dc.contributor.departmentChemistry Department, Payame Noor Universityen_US
dc.contributor.departmentChemistry Department, Payame Noor Universityen_US
dc.contributor.departmentChemistry Department, Payame Noor Universityen_US
dc.citation.volume4
dc.citation.issue435949013
dc.citation.spage414
dc.citation.epage432


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد