• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Engineering
    • Volume 33, Issue 8
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Engineering
    • Volume 33, Issue 8
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Investigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation

    (ندگان)پدیدآور
    Sandeep Kumar, Y.Rajeswara Rao, K. V. S.Sunil R., Y.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    452.3کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR  is Ultra High Molecular Weight Polyethylene (UHMWPE). Prevailing research reports that implants are restrained by tiny UHMWPE debris generated by long term friction between the femoral component and polyethylene articulating surface. This necessitates an alternative material with high wear-resistance to reduce the wear rate. Polyether ether ketone (PEEK) is one of the biopolymers expected to possess better mechanical properties and biocompatibility with surrounding tissue and hence can be suitable for orthopedic applications. In this regard, a study on UHMWPE and PEEK biopolymers was carried out and tribological behavior was examined. The effect of process parameters such as normal load and speed on the tribological performance of biopolymers were evaluated. The experiment plan was designed as per Taguchi's Design of Experiments methodology. An empirical relation between wear and process parameters was established using linear regression analysis. Microanalysis and failure analysis of worn-out surfaces of both the biopolymers was carried out using  Scanning Electron Microscopy(SEM). Results exhibit that UHMWPE had deep grooves as compared to finer grooves on PEEK indicating a low wear rate in the latter. This was also supported by the experimental results suggesting PEEK as a suitable alternative biopolymer for TKR.
    کلید واژگان
    Ti6Al4V
    Polyether Ether Ketone
    Ultra High Molecular Weight Poly Ethylene Additive Manufacturing
    Scanning electron microscopy
    Analysis of variance

    شماره نشریه
    8
    تاریخ نشر
    2020-08-01
    1399-05-11
    ناشر
    Materials and Energy Research Center
    سازمان پدید آورنده
    Department of Industrial Engineering and Management, Rashtreeya Vidyalaya College of Engineering, Bengaluru, India
    Department of Industrial Engineering and Management, Rashtreeya Vidyalaya College of Engineering, Bengaluru, India
    Department of Industrial Engineering and Management, Rashtreeya Vidyalaya College of Engineering, Bengaluru, India

    شاپا
    1025-2495
    1735-9244
    URI
    https://dx.doi.org/10.5829/ije.2020.33.08b.14
    http://www.ije.ir/article_108486.html
    https://iranjournals.nlai.ir/handle/123456789/337634

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب