      The Effect of Caspian Sea Water on Corrosion Resistance and Compressive Strength of Reinforced Concrete Containing Different SiO2 Pozzolan

      (ندگان)پدیدآور
      Borzouyi Kutenayi, S.Kiahosseini, S. R.Talebpour, M. H.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.339 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Many parameters are influenced by the diffusion of chloride on concrete in marine environments and these can affect concrete quality. In this study, the effect of water to cement ratio of 0.35, 0.40 and 0.45 on corrosion resistance and compressive strength of reinforced concrete was evaluated. Moreover, different percentages of micro silica (SiO2) including 5, 7.5 and 10% were utilized, in order to investigate the effect of pozzolanic materials on the corrosion of steel in concrete. Then cubic samples reinforced with steel bar spacing of 2.5, 5 and 7 cm from the cube surface were made and put in Caspian sea water for 5 months. During this period, corrosion potential of steel was measured by a calomel half cell (SCE). In order to finalize the evaluation of the mechanical strength of the samples, concrete pressure test was conducted and the result showed that after 40, 44 and 59 days for the bars with depth of 2.5, 5 and 7 cm, respectively and the samples prepared with water-cement ratio of 0.35, the corrosion potential was -350V versus SCE, while the compressive strength was approximately 450 kg/cm2. This result showed longer life span of this sample in comparison with other water-cement ratios. By adding micro silica to the samples up to 7.5%, the time for obtaining a corrosion potential of -350V, bars with depth of 2.5, 5 and 7 cm, was 43, 50 and 86 days, respectively, and the compressive strength of this sample was approximately 480 kg/cm2. Consequently, it is arguable that in order to achieve longer life span of corrosion and suitable compressive strength, the optimum ratio of water to cement should be 0.35 and the percentage of pozzolan SiO2 should be 7.5%.
      کلید واژگان
      Chloride
      Corrosion Potential
      Steel Corrosion
      Micro Silica

      شماره نشریه
      10
      تاریخ نشر
      2017-10-01
      1396-07-09
      ناشر
      Materials and Energy Research Center
      سازمان پدید آورنده
      Department of Engineering, Damghan Branch, Islamic Azad University, Damghan, Iran
      Department of Engineering, Damghan Branch, Islamic Azad University, Damghan, Iran
      Civil Engineering Department, School of Engineering, Damghan University, Damghan, Iran

      شاپا
      1025-2495
      1735-9244
      URI
      http://www.ije.ir/article_73027.html
      https://iranjournals.nlai.ir/handle/123456789/337602

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب