• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Engineering
    • Volume 32, Issue 10
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Engineering
    • Volume 32, Issue 10
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Direct Displacement Based Design of Reinforced Concrete Elevated Water Tanks Frame Staging

    (ندگان)پدیدآور
    Kumbhar, OnkarKumar, RatneshP L, PanaiyappanNoroozinejad Farsangi, Ehsan
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    853.7کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Elevated water tanks supported by the reinforced concrete (RC) Staging are classified as inverted pendulum structures. These are considered as structures of high post-earthquake importance and should remain functional after the seismic events. National codes of various countries recommend Force-Based Design (FBD) procedure for water tank staging, which does not ensure nonlinear performance level for a given hazard. Therefore, it becomes necessary to design these structures with a performance-based design approach like Direct Displacement-Based Design (DDBD). Many design engineers consider that the behavior of frame staging of the elevated water tank is similar to the building's frame and generally adopt the same design principles for both types of structures. However, the seismic behavior of the building frame is significantly different from frame staging due to the absence of diaphragm action at the bracing level and concentrated mass at the top level only. Therefore, it may not be rational to utilize the same DDBD procedure of the building's frame for the design of frame staging of the elevated water tanks. The present study proposes some modification in existing DDBD procedure (used for the design of frame building) based on the nonlinear time history analysis of twenty meters high RC frame staging with four different configurations. The modifications are proposed in terms of inelastic displacement profile, design displacement, effective height, and effective mass calculation. Further, the performance of the same RC frame staging designed using the proposed DDBD procedure has been assessed using nonlinear static and dynamic analyses to verify the suitability of proposed modifications.
    کلید واژگان
    Water Tank
    Direct Displacement-Based Design
    Force based design
    Seismic Hazard Level
    staging
    Lifeline

    شماره نشریه
    10
    تاریخ نشر
    2019-10-01
    1398-07-09
    ناشر
    Materials and Energy Research Center
    سازمان پدید آورنده
    Research Scholar, Visvesvaraya National Institute of Technology, Nagpur-440010, India
    Visvesvaraya National Institute of Technology, Nagpur-440010, India
    Visvesvaraya National Institute of Technology, Nagpur-440010, India
    Graduate University of Advanced Technology

    شاپا
    1025-2495
    1735-9244
    URI
    https://dx.doi.org/10.5829/ije.2019.32.10a.09
    http://www.ije.ir/article_95714.html
    https://iranjournals.nlai.ir/handle/123456789/337553