• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Engineering
    • Volume 30, Issue 8
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Engineering
    • Volume 30, Issue 8
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Stochastic Unit Commitment in the Presence of Demand Response Program under Uncertainties

    (ندگان)پدیدآور
    Valinejad, J.Oladi, Z.Barforoushi, T.Parvania, M.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.686 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In this paper, impacts of various uncertainties such as random outages of generating units and transmission lines, forecasting errors of load demand and wind power, in the presence of Demand response (DR) programs on power generation scheduling are studied. The problem is modelled in the form of a two-stage stochastic unit commitment (UC) which by solving it, the optimal solutions of UC as well as DR are obtained. Generating units' constraint, DR and transmission network limits are included. Here, DR program is considered as ancillary services (AS) operating reserve which is provided by demand response providers (DRPs. In order to implement the existent uncertainties, Monte Carlo (MC) simulation method is applied. In this respect, scenarios representing the stochastic parameters are generated based on Monte Carlo simulation method which uses the normal distribution of the uncertain parameters. Backward technique is used to reduce the number of scenarios. Then, scenario tree is obtained by combining the reduced scenarios of wind power and demand. The stochastic optimization problem is then modelled as a mixed-integer linear program (MILP). The proposed model is applied to two test systems. Simulation results show that the DR improves the system reliability and also reduces the total operating cost of system under uncertainties.
    کلید واژگان
    Ancillary services (AS)
    demand response (DR)
    stochastic optimization
    Uncertainty
    wind power

    شماره نشریه
    8
    تاریخ نشر
    2017-08-01
    1396-05-10
    ناشر
    Materials and Energy Research Center
    سازمان پدید آورنده
    Department of Electrical and Computer Engineering, Babol Noshirvani University of Technology, Babol, Iran
    Mazandaran University of Science and Technology, Babol, Iran
    Mazandaran University of Science and Technology, Babol, Iran
    Department of Electrical and Computer Engineering, University of California Davis, Davis, California

    شاپا
    1025-2495
    1735-9244
    URI
    http://www.ije.ir/article_72989.html
    https://iranjournals.nlai.ir/handle/123456789/337323

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب