      Impact of the Confluence Angle on Flow Field and Flowmeter Accuracy in Open Channel Junctions

      (ندگان)پدیدآور
      Zaji, Amir HosseinBonakdari, HosseinBonakdari, Hossein
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.430 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Open channel junction is one of the most common hydraulic structures that are used in various practical situations such as sewer, drainage, and flood control systems. Knowing the fluid flow behavior, is one of the most important topics in designing the efficient open channel junctions. The complexity and deviation of flow in the junction’s zone disrupts the proper functioning of the flowmeter devices which are located in the cross section and causing error in their measurements. Various three-dimensional Computational Fluid Dynamic (CFD) models were developed in this paper in order to study in the velocity field and flowmeter accuracy of junctions in different hydraulic conditions and confluence angles. The results showed that by increasing the confluence angle, the junction’s downstream flow becomes more complicated, and consequently, the difference between the flowmeter measured discharge values and the real discharge value becomes greater. For the junction with 30° confluence, the flowmeter discharge prediction error is equal to 2 and 6.45% in the junction’s upstream and downstream, respectively. These values increase to 6 and 38.65% for the junction’s upstream and downstream with 90° confluence, respectively.
      کلید واژگان
      CFD
      Confluence angle
      Flow Field
      Flowmeter
      Open channel junction

      شماره نشریه
      8
      تاریخ نشر
      2015-08-01
      1394-05-10
      ناشر
      Materials and Energy Research Center
      سازمان پدید آورنده
      Civil Engieering, Razi University
      Civil Engieering, Razi University
      Civil Engieering, Razi University

      شاپا
      1025-2495
      1735-9244
      URI
      http://www.ije.ir/article_72560.html
      https://iranjournals.nlai.ir/handle/123456789/337307

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب