Proposed Relationship to Design the Waffle Floor under Harmonic Vertical Loading
(ندگان)پدیدآور
Fereydouni, AbedHeydari, Mohammad Mehdijalili, rezaنوع مدرک
Textزبان مدرک
Englishچکیده
The design codes of building are mainly related to the strength of the building and there are no specific codes for the design of building with waffle floors for vibration sensitive equipment. The finite element model, ANSYS, is capable to consider the effects of floor thickness, the size of the bays and stiffness of the columns for analyzing the vibration of the waffle floors and vibration transmission along the waffle floor. Because the finite element analysis is time consuming and it needs enough expertise for modeling, in this study, an approximate relationship is proposed to design the waffle floor based on the comprehensive investigations of different effective parameters in the response of waffle floor and the results obtained from finite element analysis. This proposed relationship comforts the designers of industrial buildings and vibration sensitive equipment to attain a preliminary and appropriate outline to design the waffle floor considering the effective parameters on the floor vibration.
کلید واژگان
Waffle floorvibration
Harmonic loading
Finite Element
شماره نشریه
10تاریخ نشر
2013-10-011392-07-09
ناشر
Materials and Energy Research Centerسازمان پدید آورنده
Civil Engineering, Islamic Azad Universit,bushehr BranchCivil Engineering, University of Shiraz
Civil Engineering, Islamic Azad Universit,bushehr Branch
شاپا
1025-24951735-9244