      Comparative Performance Study of Tuned Liquid Column Ball Damper for Excessive Liquid Displacement on Response Reduction of Structure

      (ندگان)پدیدآور
      Pal, S.Roy, B. K.Choudhury, S.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      514.8کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      The tuned liquid column damper (TLCD) having a uniform cross-sectional tube of U-shaped, occupied with liquid is used as a vibrational response mitigation device. The tuned liquid column ball damper (TLCBD) is a modified TLCD, where, an immovable orifice, positioned at the middle part of the horizontal portion, is replaced by a metal ball. Different studies on the unconstrained optimization performance of TLCBD subjected to the stochastic earthquake have been performed where limitations on the maximum amplitude of liquid present in the vertical portion of the tube were not imposed. In the case of the high magnitude of earthquake and space constraint, the excessive liquid movement might get generated in the vertical portion of the tube which can create challenging circumstances. This can be taken care of by restricting the liquid movement up to a certain limit. The present investigation considers the optimum performance of the structure with TLCBD for mitigating the vibrational response with limited liquid movement in the vertical portion of the tube. A numerical study has been carried out to demonstrate the difference between constrained and unconstrained optimization of structure-TLCBD system. Numerical results show the influence of constraining cases on optimum parameters and performance behavior of the structure-TLCBD system.
      کلید واژگان
      constrained optimization
      Limited Liquid Displacement
      Response Reduction
      Tuned Liquid Column Ball Damper

      شماره نشریه
      5
      تاریخ نشر
      2020-05-01
      1399-02-12
      ناشر
      Materials and Energy Research Center
      سازمان پدید آورنده
      Civil Engineering Department, National Institute of Technology Silchar, Assam, India
      Civil Engineering Department, National Institute of Technology Silchar, Assam, India
      Civil Engineering Department, National Institute of Technology Silchar, Assam, India

      شاپا
      1025-2495
      1735-9244
      URI
      https://dx.doi.org/10.5829/ije.2020.33.05b.06
      http://www.ije.ir/article_107035.html
      https://iranjournals.nlai.ir/handle/123456789/336963

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب