• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • International Journal of Engineering
      • Volume 22, Issue 4
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • International Journal of Engineering
      • Volume 22, Issue 4
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      The Effect of Analysis Methods on the Response of Steel Dual-System Frame Buildings for Seismic Retrofitting

      (ندگان)پدیدآور
      Ahmadi, Hamid RezaHamidi Jamnani, HamedGhodrati Amiri, GH.R.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      376.5کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      In the present paper, the focus is on the evaluation of steel dual-system frame buildings using four main types of structural analysis (Linear Static, Linear Dynamic, Nonlinear Static and Nonlinear Dynamic Analyses) with regard to "Seismic Rehabilitation Code for Existing Buildings in Iran" (based on FEMA 273 and 356) where the first two authors of the article tend to follow the previous work (Section 2). The difference of the results taken from these four types of analyses and also seismic performance of the dual-system buildings will be studied in both linear and nonlinear treatments. Three 2D models which include 3 common dual-system buildings (5,10 and 15-story) have been chosen and designed subjected to earthquake based on the Standard No. 2800 of Iran (3rd revision). Then, the 2D models have been analyzed and controlled according to “Seismic Rehabilitation Code for Existing Buildings”. The selected rehabilitation goal for this research is Fair (Controlling Life Safety and Collapse Prevention in two hazard levels derived from PSHA analysis). Based on the research results, the main role of lateral load-bearing is on bracing members. The linear analysis of bracing members evaluation, has a low accuracy, in evaluation of columns the results derived from linear static analysis shows more accuracy than linear dynamic and nonlinear static analyses. Also, the accuracy of nonlinear static analysis decreases when the number of stories increases.
      کلید واژگان
      Seismic Retrofitting
      Steel Dual
      System Frame Building
      Linear analysis
      Nonlinear analysis
      Seismic Hazard Analysis

      شماره نشریه
      4
      تاریخ نشر
      2009-12-01
      1388-09-10
      ناشر
      Materials and Energy Research Center
      سازمان پدید آورنده
      Civil Engineering, University of Tarbiat Modares
      Civil Engineering, Babol Noshirvani University of Technology
      Civil Engineering , Iran University of Science and Technology

      شاپا
      1025-2495
      1735-9244
      URI
      http://www.ije.ir/article_71810.html
      https://iranjournals.nlai.ir/handle/123456789/336478

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب