Seismic Behavior of Prefabricated Column-Footing Connection
(ندگان)پدیدآور
Tasnimi, A. A.نوع مدرک
Textزبان مدرک
Englishچکیده
Results of an experimental investigation of the seismic performance of prefabricated column-footing connections are presented. Tests were conducted on six 1/4-scale prefabricated column specimens inserted into prefabricated footings in two Groups. Group-1 consisted of four specimens, which were tested under constant axial load and cyclic inelastic lateral displacements. The remaining two specimens in group-2, were subjected to cyclic inelastic lateral displacements only for comparison. Test results showed that this type of connection exhibits relatively higher ultimate strength comparable to fixed end connections, and fairly acceptable ductile behavior. Also the test results indicate the strength reduction in post-elastic state and the connection behavior as a semi-rigid joint.
کلید واژگان
PrefabricatedDuctility
Cracking
Lateral load
Earthquake
Connection
Energy dissipation
شماره نشریه
4تاریخ نشر
1999-11-011378-08-10
ناشر
Materials and Energy Research Centerسازمان پدید آورنده
Structural Engineering Research Center, International Institute of Earthquake Engineeringشاپا