    Effect of Hip Prosthesis on Photon Beam Characteristics in Radiological Physics

    (ندگان)پدیدآور
    Bhushan, ManindraTripathi, DeepakYadav, GirigeshKumar, LalitDewan, AbhinavKumar, Gourav
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    537.7کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Articles
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Aim of study is to investigate the effect of hip prosthesis on 6 and 15 MV photon beam energies. Materials and Methods: Prosthesis was kept at the level of tray position. The measurements were done on Varian Clinac-iX linac. Customized prosthesis, termed as Prosthetic Metal Implant (PMI) was made up of wrought austenitic stainless steel rod and covered with paraffin-wax. ‘Standard prosthesis' was made up of wrought titanium alloy. The dose profiles were measured for three field sizes i.e. 5, 10 and 20 cm at 100 cm SSD for 6 and 15 MV energies. The perturbation index (PI) was also calculated. Results: Perturbation caused by standard prosthesis was approximately 50% higher than that of PMI. This result may be due to difference in dimension and not because of material composition. Variation of central axis dose might be due to the dimensions of PMI used for experiment which gave intermediate response (e.g. 102.1%, 141.0% and 117.7% for Open, Standard and PMI respectively for 10x10 cm2 field size, 10 cm depth and 15MV photon beam setup )as compared to the ‘open' and ‘standard' prosthesis. Percentage dose at 10 cm for 6MV photon increased rapidly with field-size for PMI. But, for 15MV photon, difference was not significant. Surface dose (Ds) for PMI remains significantly higher for smaller field. Conclusion: The perturbation index varied from 0.05 to 0.22 for the measured energies and gave an idea to the planner to assess the behavior of the prosthesis. This range is applicable for both type of implants and for all clinical field-sizes. The attenuation caused by the prosthesis was significant and this effect should be considered in the treatment planning calculations.
    کلید واژگان
    Prosthesis
    Photon
    PDD
    Surface dose
    Perturbation Index
    Medical Physics

    شماره نشریه
    6
    تاریخ نشر
    2020-06-01
    1399-03-12
    ناشر
    West Asia Organization for Cancer Prevention (WAOCP)
    سازمان پدید آورنده
    Division of Medical Physics and Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi (India)-110085, India.
    Amity School of Applied Sciences, Amity University (AUUP), NOIDA, India.
    Division of Medical Physics and Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi (India)-110085, India.
    Division of Medical Physics and Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi (India)-110085, India.
    Division of Medical Physics and Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi (India)-110085, India.
    Division of Medical Physics and Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi (India)-110085, India.

    شاپا
    1513-7368
    2476-762X
    URI
    https://dx.doi.org/10.31557/APJCP.2020.21.6.1731
    http://journal.waocp.org/article_89140.html
    https://iranjournals.nlai.ir/handle/123456789/33533

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب