    Investigating the microbial quality of cooler drinking water of hospitals, clinics and health centres of Behbahan in 2014

    (ندگان)پدیدآور
    Baboli, ZeynabNeisi, AbdolkazemGhaed Rahmat, ZeinabAlidosti, MasoumehBnadeei Nejad, Ahmad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    255.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background and aims: The main cause of many problems in developing countries is related to the provision of safe drinking water. Since the health of drinking water is important in the busy centers such as hospitals, clinics and health centers, this study was done to investigate the role of water coolers connected to the municipal system in microbial quality of drinking water in Behbahan city. Methods: In this study, the samples were provided from all influent and effluent 30 water coolers located in hospitals, clinics and health centers in the Behbahan. They were carried out and transferred to the laboratory. Then, the amounts of total coliforms and fecal coliforms, residual chlorine, pH and temperature were measured. Collected data were analyzed using SPSS and Excel software. Results: The results showed that the average residual chlorine in input and output of the mentioned water coolers is significantly more than the standard values. Total and fecal coliforms in the input and output of water coolers are also more than the standard values. At the same time, both indicators in the output of water cooler were increased rather than the input one. By using paired t-test, a significant relationship was found between the amount of total coliform, fecal coliform and residual chlorine before and after of water cooler. Conclusions: The results showed negative effects of water coolers on microbial quality of water. If constant control, monitoring and inspections proceedings were done, these contaminations would be reduced significantly.
    کلید واژگان
    Drinking water
    water cooler
    Microbial quality
    fecal coliform
    Behbahan
    Environmental Health

    شماره نشریه
    2
    تاریخ نشر
    2016-06-01
    1395-03-12
    ناشر
    Shahrekord University of Medical Sciences
    سازمان پدید آورنده
    Environmental Health Engineering Dept., Behbahan Faculty of Medical Sciences, Behbahan, I.R. Iran
    Environmental Health Engineering Dept., Ahvaz Jundishapur University of Medical Sciences, Ahvaz, I.R. Iran
    Environmental Health Engineering Dept., Behbahan Faculty of Medical Sciences, Behbahan, I.R. Iran
    Public Health Dept., Behbahan Faculty of Medical Sciences, Behbahan, I.R. Iran.
    Environmental Health Engineering Dept., Behbahan Faculty of Medical Sciences, Behbahan, I.R. Iran

    شاپا
    2383-4366
    URI
    http://ijer.skums.ac.ir/article_16361.html
    https://iranjournals.nlai.ir/handle/123456789/334087

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب