    Effect of Bolus Frequency and Its Thickness in Postmastectomy Three-dimensional Conformal Radiotherapy on Skin Dose for Superposition Algorithm

    (ندگان)پدیدآور
    BAHHOUS, KarimZERFAOUI, MustaphaEL KHAYATI, Naima
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.254 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: The postmastectomy radiotherapy uses bolus to improve the coverage close to the skin; however, it needs to be removed in case of severe skin toxicity. This study investigated the effect of bolus parameters (i.e., frequency and thickness) for the superposition algorithm on skin dose in postmastectomy three-dimensional conformal radiotherapy (3D-CRT). Material and Methods: The present study was carried out ona total of 22 patients. First, all the plans were calculated without using bolus. Then, the plans were recalculated using different bolus frequencies (5, 10, 15, 20, 25) and thicknesses (0.5 and 1 cm). To evaluate the dose delivered to the skin, a 2-mm thick skin was profiled, and statistical analysis was performed by studying the dosimetric parameters (i.e., minimum, mean, and maximum) of chest wall skin. Results: The superficial coverage of planning target volume (PTV) was better by using bolus. In the case of skin, the bolus thickness had a significant impact on the minimum and mean doses for all bolus frequencies , while there was no significant effect on the maximum before 20-bolus frequency. The bolus frequency increase demonstrated a significant difference on all dosimetric parameters of the skin , except the maximum showed no significant difference between 0 and 5-bolus frequencies . Conclusion: The obtained results indicated that the bolus use had generally a significant effect on the chest wall skin dosimetric parameters depending on bolus frequency and thickness. Therefore, the choice of bolus frequency and bolus thickness can affect the clinical decisions in certain cases.
    کلید واژگان
    Bolus
    Postmastectomy
    Chest Wall
    Skin dose
    Superposition
    Conformal Radiotherapy
    Medical Physics
    Physics of Radiotherapy

    شماره نشریه
    6
    تاریخ نشر
    2019-11-01
    1398-08-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    ESMaR, Faculty of Science, Mohammed V University in Rabat, Rabat, Morocco
    LPMR, Faculty of Science, University Mohamed 1st, Oujda, Morocco
    ESMaR, Faculty of Science, Mohammed V University in Rabat, Rabat, Morocco

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.33900.1426
    http://ijmp.mums.ac.ir/article_11938.html
    https://iranjournals.nlai.ir/handle/123456789/325003

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب