    A Fast, Robust, Automatic Blink Detector

    (ندگان)پدیدآور
    Sayahzadeh, JavadPourreza, HamidrezaSalehi Fadardi, Javad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    979.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction “Blink" is defined as closing and opening of the eyes in a small duration of time. In this study, we aimed to introduce a fast, robust, vision-based approach for blink detection. Materials and Methods This approach consists of two steps. In the first step, the subject's face is localized every second and with the first blink, the system detects the eye's location and creates an open-eye template image. In the second step, the eye is tracked, using sum of squared differences (SSD). This system can classify the state of the eyes as open, closed, or lost, using the SSD-based classifier. If the eyes are closed as in usual blinking, the blink will be detected. To classify eyes as closed or open, two adaptive thresholds were proposed; therefore, factors such as the subject's distance from the camera or environment illumination did not affect the system performance. In addition, in order to improve system performance, a new feature, called "peak-to-neighbors ratio", was proposed. Results The accuracy of this system was 96.03%, based on the evaluation on Zhejiang University (ZJU) dataset, and 98.59% in our own dataset. Conclusion The present system was faster than other systems, which use normalized correlation coefficient (NCC) for eye tracking, since time complexity of SSD is lower than that of NCC. The achieved processing rate for ZJU dataset was 35 fps.
    کلید واژگان
    Eye Localization
    Blink Detection
    Sum of Squared Differences
    Medical Engineering
    Medical Physics

    شماره نشریه
    4
    تاریخ نشر
    2014-12-01
    1393-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Machine Vision Lab., Computer Eng. Department, Ferdowsi University of Mashhad, Iran
    Machine Vision Lab., Computer Eng. Department, Ferdowsi University of Mashhad, Iran
    Faculty of Educational and Psychological Sciences, Ferdowsi University of Mashhad, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2014.3571
    http://ijmp.mums.ac.ir/article_3571.html
    https://iranjournals.nlai.ir/handle/123456789/324988

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب