      Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

      (ندگان)پدیدآور
      BahreyniToossi, Mohammad TaghiMalekzadeh, Malakeh
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      400.5کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an area or an institution as a Local DRL (LDRL). Materials and Methods To establish DRL for diagnostic X-ray examinations of children in KhorasanRazavi province, data were collected from 627 pediatric patients. The average of entrance surface doses (ESDs), arising from chest and abdomen examinations, were examined for three different age groups. Results Local DRL (LDRL) were calculated to be 77, 126, and 138 µGy for chest examinations of Conclusion Our findings revealed that local DRLs in this study are higher than the corresponding values, recommended by the Commission of European Communities (CEC) and National Radiological Protection Board (NRBP). Higher ESDs acquired for chest examination were related to the use of low kVp, relatively high mAs in all centers, and use of grid for most of the patients.
      کلید واژگان
      Diagnostic Reference Level
      Pediatric
      Radiology
      Entrance Surface Dose
      Iran
      Medical Physics
      Physics of Diagnostics Radiology
      Radiation Detection & Measurement

      شماره نشریه
      4
      تاریخ نشر
      2014-12-01
      1393-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Medical Physics Research Center, Medical Physics Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
      Paramedical School. Babol University of Medical Sciences. Babol. Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2014.3566
      http://ijmp.mums.ac.ir/article_3566.html
      https://iranjournals.nlai.ir/handle/123456789/324983

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب