      Evaluation of Six-Dimensional Cranial Target Positioning Accuracy in Two Different Immobilization Methods Using Exactrac System

      (ندگان)پدیدآور
      Kasirajan, Tamil SelvanGanesan, PadmaMurugesan Kesavan, RevathyN, Arunai Nambi RajK, SenthilnathanP, Ramesh Babu
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.108 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: The aim of this study was to determine the accuracy of two different immobilization methods in patient positioning in cranial radiotherapy. The six-dimensional (6D) target localization accuracy of using a dedicated stereotactic mask was compared with that of a conventional head mask by the ExacTrac system. Material and Methods: A total of 56 patients with cranial lesions were included in this study (26 patients with a dedicated stereotactic mask and 30 subjects with a conventional head mask). The ExacTrac image-guided positioning system was utilized to obtain daily translational and rotational patient positioning displacement from the intended position. The 6D setup data was analyzed to obtain population mean, systematic and random errors, and three-dimensional (3D) vector shifts in all the patients. Results: The population mean values of setup errors were comparable with both immobilization systems; however, the spread as indicated by population systematic and population random errors was more in the use of a conventional head mask. The mean values of the 3D vector shifts were 2.09±1.00 and 4.51±3.38 mm with the use of a dedicated stereotactic mask and conventional head mask, respectively. The frequency distribution of maximum rotational deviation and statistical analysis demonstrated a significant difference in immobilization accuracy between stereotactic immobilization and 3-clamp immobilization (PConclusion: The results revealed that there was a significant reduction in target positioning errors with a dedicated stereotactic mask, compared to that with a conventional cranial mask. Furthermore, a dedicated stereotactic mask is required to keep rotational deviations within system correctable limits.
      کلید واژگان
      Radiotherapy
      patient positioning
      Radiosurgery
      Radiotherapy Setup Errors
      Immobilization
      Medical Physics
      Physics of Radiotherapy

      شماره نشریه
      5
      تاریخ نشر
      2020-09-01
      1399-06-11
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Department of oncology, Medical Physicist, Apollo Cancer Hospital, Hyderabad, INDIA
      Medical Physicist, Department of Oncology, Apollo Cancer Hospital,Hyderabad, Telangana,INDIA
      Chief Medical Physicist,Department of Oncology, Apollo Cancer Hospital,Hyderabad, Telangana,INDIA
      Professor, Centre for Biomaterials, cellular & Molecular Theranostics, VIT University, Vellore,Tamilnadu, INDIA
      Professor, Department of Physics, School of Advanced Sciences, VIT university, Vellore, Tamilnadu, INDIA
      Professor, Department of physics, School pf Advanced Sciences, VIT University,Vellore, Tamilnadu,INDIA

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2019.35652.1448
      http://ijmp.mums.ac.ir/article_14033.html
      https://iranjournals.nlai.ir/handle/123456789/324977

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب