      Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose

      (ندگان)پدیدآور
      Moey, Soo-FoonFatin Naimah, Mohamad Asri
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      863.7کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise ratio and can be related to image quality. The aim of this study was to evaluate the influence of EI on image quality and radiation dose for the posterior anterior (PA) chest radiography. Material and Methods: This study was conducted in three phases, namely pre-optimization, experimental, and post-optimization. A total of 60 patients that could fulfill the inclusion and exclusion criteria for the PA chest radiography were recruited. The radiographic technical parameters, dose area product, and EI were recorded. Radiographs were printed and evaluated by two recruited radiologists using the modified evaluation criteria established by the Commission of European Communities in 1996. Results: Statistical analysis using Spearman's Rho Correlation showed an insignificant relationship between EI and image quality for the PA chest radiography (P>0.05). Conversely, there was a significant relationship between EI and radiation dose (0.05). Conversely, there was a significant relationship between EI and radiation dose (PConclusion: TheEI can be used as an indirect measure of image quality and radiation dose. The EI does not directly determine image quality since the radiographic technique and parameters used can affect image quality. Although EI can be used as a measure of radiation dose, it cannot provide an accurate measurement of the radiation received by the patient.
      کلید واژگان
      Chest
      Image Quality
      Radiation Dose
      Digital Radiography
      Medical Imaging & Image Processing
      Medical Physics
      Physics of Diagnostics Radiology

      شماره نشریه
      4
      تاریخ نشر
      2019-07-01
      1398-04-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      International Islamic University Malaysia
      International Islamic University Malaysia

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2018.33156.1404
      http://ijmp.mums.ac.ir/article_11901.html
      https://iranjournals.nlai.ir/handle/123456789/324969

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب