      Assessment of Patient Dose from CT Examinations in Khorasan, Iran

      (ندگان)پدیدآور
      Bahreyni Toossi, Mohammad TaghiBahrami, Mohammad
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      226.6کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two reference dose quantities have been defined in order to promote the use of good technique in CT. These are weighted CT dose index (CTDIw) in (mGy) for a single slice in serial scanning or per rotation in helical scanning, and dose–length product (DLP) per complete examination (mGy.cm), All measurements were performed using a pencil shaped ionization chamber introduced into polymethyl methacrylate cylindrical brain and body phantoms. This survey was performed on 7 CT scanners in Khorasan Province-Iran. Results DLP for brain, chest, abdomen and pelvic examinations had a range of 255 - 1026, 76-1277, 48-737, 69-854 mGy.cm, respectively. Conclusion The results obtained in this study show that the DLP values obtained in this province are lower than European Commission reference dose levels (EC RDL), in other words performance of all the scanners were satisfactory.
      کلید واژگان
      DLP
      Ionization Chamber
      Computed Tomography (CT)
      Medical Physics
      Radiation Detection & Measurement

      شماره نشریه
      4
      تاریخ نشر
      2012-12-01
      1391-09-11
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Medical Physics Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran Department of Medical Physics, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
      Department of Medical Physics, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2013.465
      http://ijmp.mums.ac.ir/article_465.html
      https://iranjournals.nlai.ir/handle/123456789/324949

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب