• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Issue 4
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Issue 4
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Evaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy

    (ندگان)پدیدآور
    Shahedi, FatemehMomennezhad, MehdiNasseri, shahrokhGholamhosseinian, Hamid
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.287 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying corrections for the uncertainty of patient set-up. Material and Methods: Firstly, the safety features were verified, and the uniformity of EPID response was evaluated using flat panel detector. Additionally, the contrast and spatial resolutions of the EPID were assessed using detail counting of the Los Vegas phantom images by visualization method and measuring the modulation transfer function using edge technique, respectively. Moreover, a combination of smoothing methods was used for optimal use of edge detection algorithm for the noisy portal images. Finally, the location of the central ray on the EPID surface at different gantry angles was determined to evaluate the mechanical stability of the supporting arm. Results: The safety interlocks were found to be functional.The EPID response variation was less than 3% according to the results obtained from the detector. The contrast resolution met the recommended tolerance; however, the visualization method was widely observer-dependent. The value of f50 for spatial resolution was 0.401±0.005 lp/mm for the photon energy of 6 MV. The supporting arm deviation was within ±1 mm. Conclusion: The periodic QA of image guidance system gave confidence to apply the corrections for set-up in clinic.
    کلید واژگان
    Quality Assurance
    Radiotherapy
    Imaging
    Medical Physics
    Physics of Radiotherapy

    شماره نشریه
    4
    تاریخ نشر
    2018-10-01
    1397-07-09
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
    Medical Physics Research center, Mashhad University of Medical Sciences, Mashhad, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.27401.1287
    http://ijmp.mums.ac.ir/article_10360.html
    https://iranjournals.nlai.ir/handle/123456789/324921

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب