      Silastic Thickness Optimization in Uveal Melanoma Brachytherapy by Monte Carlo Method

      (ندگان)پدیدآور
      Eidi, RamezanAghamiri, Seyed MahmoudrezaSheibani, ShahabJaberi, RaminPourbeigi, HosseinMashayekhi Galatoiyeh, MohsenHosseini Daghigh, Seyed Mohsen
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      388.1کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction In order to treat uveal Melanoma , first, radioactive seeds are laid on a silicone- made substance which is called Silastic after that they are inserted in the plaque, and finally, this plaque containing silicone-made substance is stitched to the sclera surface. The dose gradient within the tumor and healthy tissues can be varied due to changing the Silastic thickness between sclera surface and radioactive seeds. In turn, this leads to difference in the amount of absorbed dose of tumor and healthy tissues. Present study is to investigate the optimum Silastic thickness in uveal Melanoma brachytherapy.  Materials and Methods To measure changes of depth dose of the plaque in a sphere with a radius of 12 mm, MCNP4C code was applied. Exact specifications of a 20-mm Collaborative Ocular Melanoma Study (COMS) plaque, Silastic and three I-125 seed sources, 6711 model were integrated in simulation. Dose calculations were performed using F6 tally in spheres with a radius of 0.2 mm. Results By measuring the changes of dose rate of plaque in distances of 0.2 to 18 mm from the sclera surface and having the prescribed dose for the absolute treatment of eye melanoma, final absorbed doses by tumor and healthy tissues for each different Silastic thicknesses of 0, 0.5, 1, 1.5, and 2 were calculated. Conclusion Considering the results and sclera tolerance, it was concluded that the thickness of Silastic must not exceed 0.5 mm, because increasing the Silastic thickness from this area, increases absorbed dose by healthy tissues and also the treatment time.
      کلید واژگان
      Uveal Melanoma
      I-125 Source
      Monte Carlo
      Silastic
      Medical Application of Computer Simulation
      Medical Physics
      Physics of Radiotherapy

      شماره نشریه
      1
      تاریخ نشر
      2014-03-01
      1392-12-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Radiation Medicine Department, Shahid Beheshti University, Tehran, Iran
      Department of Nuclear Research Center, Atomic Energy Organization of Iran, Tehran, Iran
      Department of Nuclear Research Center, Atomic Energy Organization of Iran, Tehran, Iran
      Imam Khomeini Hospital, Tehran University of Medical Science, Tehran, Iran
      Department of Nuclear Research Center, Atomic Energy Organization of Iran, Tehran, Iran
      Physics Department, Hakim Sabzevari University, Sabzevar, Iran
      Radiation Medicine Department, Shahid Beheshti University, Tehran, Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2014.2624
      http://ijmp.mums.ac.ir/article_2624.html
      https://iranjournals.nlai.ir/handle/123456789/324883

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب