نمایش مختصر رکورد

dc.contributor.authorPark, Hyo-Kuken_US
dc.contributor.authorCho, Jae-Hwanen_US
dc.contributor.authorKim, sungchulen_US
dc.date.accessioned1399-07-09T07:35:08Zfa_IR
dc.date.accessioned2020-09-30T07:35:08Z
dc.date.available1399-07-09T07:35:08Zfa_IR
dc.date.available2020-09-30T07:35:08Z
dc.date.issued2019-03-01en_US
dc.date.issued1397-12-10fa_IR
dc.date.submitted2018-07-10en_US
dc.date.submitted1397-04-19fa_IR
dc.identifier.citationPark, Hyo-Kuk, Cho, Jae-Hwan, Kim, sungchul. (2019). Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients. Iranian Journal of Medical Physics, 16(2), 171-178. doi: 10.22038/ijmp.2018.32544.1392en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2018.32544.1392
dc.identifier.urihttp://ijmp.mums.ac.ir/article_11425.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324825
dc.description.abstract<strong><em>Introduction:</em></strong> This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. <strong><em>Material and Methods:</em></strong> This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree of freedom) treatment couch. The dosimetric effects regarding the application of the rotational setup error were examined by comparing the treatment plans. <strong><em>Results:</em></strong> The mean patient setup errors at the lateral (X-axis), longitudinal (Y-axis), and vertical (Z-axis) directions were 0.1±1.4, 0.0±1.1, and -0.4±1.2 mm, respectively. The pitch, roll, and yaw were -0.29±0.61°,-0.42±0.98°, and -0.53±0.69°, respectively. When an absolute value was taken for the setup error, the mean error was 1.06±0.14 mm at the three translation directions, and the error of rotation was 0.82±0.14°, showing a larger error than that of translation. In terms of the mean dose difference by each region of interest (ROI) before and after correcting for the rotational setup error on the treatment plan, Brain_max was 2.17 Gy, and Brain_mean was 0.28 Gy, whereas the maximum and mean of Brain_stem were -3.58 and -4.43 Gy, respectively. These findings suggested a dose difference according to the correction of the rotational setup error. <strong><em>Conclusion: </em></strong>This study indicated that the dose effect is influenced by the rotational setup error in VMAT of brain tumor patients. Moreover, the 6DoF positional correction could reduce the positional uncertainties and deliver a more accurate dose.en_US
dc.format.extent1193
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2018.32544.1392
dc.subjectVolumetric modulated arc radiotherapyen_US
dc.subjectCone beam computed tomographyen_US
dc.subjectSetup erroren_US
dc.subjectDoseen_US
dc.subjectMedical Physicsen_US
dc.subjectPhysics of Radiotherapyen_US
dc.titleDosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patientsen_US
dc.typeTexten_US
dc.typeOriginal Paperen_US
dc.contributor.departmentDepartment of Radiation Oncology, Yonsei Cancer Center, Seoulen_US
dc.contributor.departmentDepartment of Radiological Technology, Ansan University, Ansanen_US
dc.contributor.departmentRadiological Science, Gachon University Medical Campus, Incheon, Koreaen_US
dc.citation.volume16
dc.citation.issue2
dc.citation.spage171
dc.citation.epage178
nlai.contributor.orcid0000-0001-7112-3866
nlai.contributor.orcid0000-0002-4195-1297


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد