    Assessment of Patients’ Entrance Skin Dose from Diagnostic X-ray Examinations at Public Hospitals of Akwa Ibom State, Nigeria

    (ندگان)پدیدآور
    Nsikan U, EsenR. I, Obed,
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    610.4کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction High doses of ionizing radiation can lead to adverse health outcomes such as cancer induction in humans. Although the consequences are less evident at very low radiation doses, the associated risks are of societal importance. This study aimed at assessing entrance skin doses (ESDs) in patients undergoing selected diagnostic X-ray examinations at public hospitals of Akwa Ibom State, Nigeria. Materials and Methods In total, six examinations were performed on 720 patients in this study.   CALDose_X5 software program was used in estimating ESDs based on patients' information and technical exposure parameters. Results The estimated ESDs ranged from 0.59 to 0.61 mGy for PA and RLAT projections of the thorax, respectively. ESDs for the AP and RLAT projections of the cranium were 1.65 and 1.48 mGy, respectively. Also, ESD values for the AP view of the abdomen and pelvis were 1.89 and 1.88 mGy, respectively. The mean effective dose was within the range of 0.021-0.075 mGy for the thorax (mean= 0.037), 0.008-0.045 mGy for the cranium (mean= 0.016), 0.215-0.225 mGy for the abdomen (mean= 0.219) and 0.101-0.119 mGy for the pelvis (mean= 0.112). Conclusion The obtained results were comparable to the international reference dose levels, except for the PA projection of the thorax. Therefore, quality assurance programs are required in diagnostic X-ray units of Nigeria hospitals. The obtained findings add to the available data and can help authorities establish reference dose levels for diagnostic radiography in Nigeria.
    کلید واژگان
    Entrance Skin Dose
    diagnostic X-ray Examination
    Akwa Ibom
    Medical Physics
    Physics of Diagnostics Radiology
    Radiation Detection & Measurement

    شماره نشریه
    2
    تاریخ نشر
    2015-06-01
    1394-03-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Dept. of Physic, University of Ibadan, Nigeria
    Hospitals on Captions Should Be Corrected To Initial Capitals, Nigeria

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2015.4772
    http://ijmp.mums.ac.ir/article_4772.html
    https://iranjournals.nlai.ir/handle/123456789/324796

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب