      Investigation of LINAC Structural Effects on Photoneutron Specified Parameters Using FLUKA code

      (ندگان)پدیدآور
      Ashrafinia, MohammadHadadi, AsgharSardari, DariushSaeedzadeh, Elham
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.450 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: The utilization of high-energy photons in the medical linear accelerator can lead to photoneutron production. This study aimed to evaluate the effect of the physical components of the head, including flattening filter (FF) andmultileaf collimator (MLC), as well as the dependence of therapeutic field size on the photoneutron spectrum, dose, and flux. Material and Methods: The present study reported the simulation of the fundamental linac head components of the Varian Clinac 2100 performing in X-ray mode with 18 MV energy by the FLUKA code. The percentage depth dose and lateral dose profile were measured using a PTW thimble chamber to ensure the simulation reliability. Results: Photoneutron spectrum analysis indicated that neutrons with highest relative biological effectiveness were delivered to the phantom surface, and opening the field from 0×0 to 40×40  shifted the spectrum by 24.545% to the higher energies. The target and the vicinity parts played the most prominent roles in neutron contamination. The relationship between the field size and the photoneutron dose was non-linear, and it reached a peak of 20×20 . Although using small fields formed by the MLC contribute to a lower dose compared to those shaped by the jaws, MLC-equipped machines result in 21.98% higher dose. Moreover, the flattening filter removal unexpectedly increased the isocenter photoneutron dose by 11.63%. This undesirable dose can be up to 2.54 mSv/Gy for the reference field at the isocenter while the out-of-field dose is about 0.5 mSv/Gy for most of the field dimensions. Conclusion: As a result, it is critical to consider this unwanted absorbed dose, which is seriously influenced by the implemented therapeutic conditions.
      کلید واژگان
      Fast Neutrons
      Linac
      Monte Carlo
      FLUKA
      Medical Application of Computer Simulation
      Medical Physics
      Physics of Radiotherapy

      شماره نشریه
      1
      تاریخ نشر
      2020-01-01
      1398-10-11
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Department of Medical Radiation Engineering Science and Research Branch, Islamic Azad University, Tehran, Iran
      Department of Medical Radiation Engineering Science and Research Branch, Islamic Azad University, Tehran, Iran
      Department of Medical Radiation Engineering Science and Research Branch, Islamic Azad University, Tehran, Iran
      Department of Medical Radiation Engineering Science and Research Branch, Islamic Azad University, Tehran, Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2019.37678.1481
      http://ijmp.mums.ac.ir/article_12691.html
      https://iranjournals.nlai.ir/handle/123456789/324744

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب