    Investigation of LINAC Structural Effects on Photoneutron Specified Parameters Using FLUKA code

    (ندگان)پدیدآور
    Ashrafinia, MohammadHadadi, AsgharSardari, DariushSaeedzadeh, Elham
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.450 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: The utilization of high-energy photons in the medical linear accelerator can lead to photoneutron production. This study aimed to evaluate the effect of the physical components of the head, including flattening filter (FF) andmultileaf collimator (MLC), as well as the dependence of therapeutic field size on the photoneutron spectrum, dose, and flux. Material and Methods: The present study reported the simulation of the fundamental linac head components of the Varian Clinac 2100 performing in X-ray mode with 18 MV energy by the FLUKA code. The percentage depth dose and lateral dose profile were measured using a PTW thimble chamber to ensure the simulation reliability. Results: Photoneutron spectrum analysis indicated that neutrons with highest relative biological effectiveness were delivered to the phantom surface, and opening the field from 0×0 to 40×40  shifted the spectrum by 24.545% to the higher energies. The target and the vicinity parts played the most prominent roles in neutron contamination. The relationship between the field size and the photoneutron dose was non-linear, and it reached a peak of 20×20 . Although using small fields formed by the MLC contribute to a lower dose compared to those shaped by the jaws, MLC-equipped machines result in 21.98% higher dose. Moreover, the flattening filter removal unexpectedly increased the isocenter photoneutron dose by 11.63%. This undesirable dose can be up to 2.54 mSv/Gy for the reference field at the isocenter while the out-of-field dose is about 0.5 mSv/Gy for most of the field dimensions. Conclusion: As a result, it is critical to consider this unwanted absorbed dose, which is seriously influenced by the implemented therapeutic conditions.
    کلید واژگان
    Fast Neutrons
    Linac
    Monte Carlo
    FLUKA
    Medical Application of Computer Simulation
    Medical Physics
    Physics of Radiotherapy

    شماره نشریه
    1
    تاریخ نشر
    2020-01-01
    1398-10-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Medical Radiation Engineering Science and Research Branch, Islamic Azad University, Tehran, Iran
    Department of Medical Radiation Engineering Science and Research Branch, Islamic Azad University, Tehran, Iran
    Department of Medical Radiation Engineering Science and Research Branch, Islamic Azad University, Tehran, Iran
    Department of Medical Radiation Engineering Science and Research Branch, Islamic Azad University, Tehran, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2019.37678.1481
    http://ijmp.mums.ac.ir/article_12691.html
    https://iranjournals.nlai.ir/handle/123456789/324744

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب