      Pseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm

      (ندگان)پدیدآور
      Yousefi Moteghaed, NiloofarMostaar, Ahmad
      Thumbnail
      نوع مدرک
      Text
      Conference Proceedings
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue structures with registration on the CT images. Unfortunately, this causes systematic errors during the registration of MRI and CT images. The purpose of this study is to investigate the possibility of removing the CT simulator images and replacing it with pseudo-CT images (which created by MRI images) for the electron density calculation in radiotherapy treatment planning.   Materials and Methods: The pseudo-CT images were generated for 10 randomly chosen patients with brain disease. Data consisted of image voxels chosen within the segmented area of the brain in both MRI and CT images. The relation between MRI intensity and electron density was derived from HU converted model by fuzzy look up table algorithm.   Results: It was found that the MRI intensity value is related to the HU value within different parts such as skull bone, sinus, and brain. The mean prediction errors of the conversion model are -0.53, -0.082, 0.0145HU in brain, skull and air regions respectively. The mean absolute errors are 19.40 , 50.53,1.22 Conclusion: The proposed method enables generation of pseudo-CT data for the different segmented part of the brain from MRI series with appropriate mean prediction errors.
      کلید واژگان
      magnetic resonance imaging
      Radiation Therapy
      computer tomography
      Treatment Planning

      شماره نشریه
      12
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Department of Biomedical Engineering and Medical Physics, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
      Department of Biomedical Engineering and Medical Physics, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2018.13116
      http://ijmp.mums.ac.ir/article_13116.html
      https://iranjournals.nlai.ir/handle/123456789/324705

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب