      Breast dose in conventional and digital mamography

      (ندگان)پدیدآور
      Rezapour, JafarPaydar, RezaMostaar, Ahmad
      Thumbnail
      نوع مدرک
      Text
      Conference Proceedings
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography for breast cancer screening is a controversial subject. This research was done to compare the breast dose in the conventional and digital mammography devices that used in mammography centers in Tabriz city on 1395.   Materials and Methods: This research is a descriptive study. In the first three mammograms, according to the instructions of the Atomic Energy Organization of Iran (AEOI) for quality control were tested. Information about 322 patients who for mammography went to four centers over four months were collected, then the values of average dose of mammary glands in the mammogram images as milli-Gray (mGy) were calculated and analyzed.   Results: In the 4 clinics, the mean values of compressed tissue thickness in the conventional mammography device for CC and MLO were 4.01 ± 0.92 cm and 4.49 ± 1.63 cm and the dose values were 1.53 ± 0.58 mGy and 1.58 ± 0.59 mGy respectivel, P-value that received is 1. Also the mean values of compressed tissue thickness in digital mammography device for CC and MLO were 5.8 ± 1.00 cm and 6.30 ± 1.01 cm and the dose values 2.07 ± 0.71 mGy and 2.15 ± 0.69 mGy were obtained respectively and also p-value is received 0.925.   Conclusion: According to this study, it seems that despite the benefits of digital mammography on the conventional mammography, digital mammography device has more average absorbed dose rather than conventional mammography device. Due to the higher absorbed dose, doing of regular quality control and dose reduction techniques are recommended in digital mammography.
      کلید واژگان
      Breast average dose
      Mammography
      Breast Cancer

      شماره نشریه
      12
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
      Department of Radiology, Faculty of Paramedicine, Iran University of Medical Sciences, Tehran, Iran.
      Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2018.13074
      http://ijmp.mums.ac.ir/article_13074.html
      https://iranjournals.nlai.ir/handle/123456789/324692

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب