      Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

      (ندگان)پدیدآور
      Shirani Tak Abi, KavehNedaie, Hassan AliGharaati, HussainHassani, HosseinSalimi, MarziehKhodaBakhshi, RezaNezhad Dadgar, FaridRezaie Yazdi, MaliheRezaie Yazdi, Maryam
      Thumbnail
      نوع مدرک
      Text
      Conference Proceedings
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf collimators and also compensators with optimum shapes in step and shoot (SAS) and compensator-based method, respectively. Materials and Methods: Prescribed dose was 80 Gy for both IMRT procedures and 70 Gy for 3D CRT. Treatment plans of 15 prostate cancer candidates were compared to target the minimum dose, maximum dose, V 76 Gy (for IMRT plans) V 66.5 Gy (for 3D CRT), mean dose, conformity index (CI), and homogeneity index (HI). Results: Dose conformity in compensators-based IMRT was better than SAS and 3D CRT. The same outcome was also achieved for homogeneity index. The target coverage was achieved 95% of prescribed dose to 95% of planning target volume (PTV) in 3D CRT and 95% of prescribed dose to 98% of PTV in IMRT methods. IMRT increases maximum dose of tumor region, improves CI and HI of target volume, and also reduces dose of organs at risks. Conclusion: Results of this study showed that both IMRT methods provide better target coverage in comparison of 3D CRT. In SAS technique, maximum dose reduced compared with compensator-based IMRT while, in the later method, CI and HI improved; it must be mentioned that 3D CRT also had the acceptable HI and CI results. IMRT approaches represented better homogeneity and conformity over 3D CRT and in comparison of two IMRT methods, all acceptable results can be achieved in compensator IMRT.
      کلید واژگان
      IMRT
      3DCRT
      conformity index
      Homogeneity Index
      step and shoot
      compensator

      شماره نشریه
      12
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Kaveh Shirani Tak Abi, Medical Physicist of Sina Radiotherapy Oncology Department, Bu Ali Hospital, Tehran, Iran.
      Hassan Ali Nedaie, Assistant Prof. of Medical Physics, Radiotherapy Oncology Department, Tehran University of Medical Sciences, Tehran, Iran.
      Hussain Gharaati, Prof. of Medical Physics, Radiotherapy Oncology Department, Tehran University of Medical Sciences, Tehran, Iran.
      Hossein Hassani, M. Sc of Medical Radiation Engineering, Department of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran.
      Marzieh Salimi, PhD. Candidate of Medical Physics, Medical Physics and Engineering Department, Tehran University of Medical Sciences, Tehran, Iran.
      Reza KhodaBakhshi, Radiation Oncologist, Consultant and Executive Director of Sina Radiotherapy Oncology Department, Bu Ali Hospital, Tehran, Iran.
      Farid Nezhad Dadgar, Assistance Prof. of Radiation Oncology, Sina Radiotherapy Oncology Department, Bu Ali Hospital, Islamic Azad University, Medical College, Tehran, Iran.
      Malihe Rezaie Yazdi, Medical physicist of Iran Mehr Radiotherapy Oncology Department, Iran Mehr Hospital, Birjand, Iran.
      Maryam Rezaie Yazdi, Medical physicist of Iran Mehr Radiotherapy Oncology Department, Iran Mehr Hospital, Birjand, Iran.

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2018.13068
      http://ijmp.mums.ac.ir/article_13068.html
      https://iranjournals.nlai.ir/handle/123456789/324686

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب