      Evaluation of CorePlanTM treatment planning system for 6 and 15 MV photon irradiation

      (ندگان)پدیدآور
      Seifi Makrani, DanialPourfallah, Tayyeb
      Thumbnail
      نوع مدرک
      Text
      Conference Proceedings
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: Radiotherapy is an effective modality to treat esophageal carcinoma. Due to various inhomogenous tissues with a variety of physical and radiological properties which can cause uncertainty in accurate dose calculations in radiation therapy, accuracy of TPS is very important. The aim of this study was to quantify dose calculation accuracy of CoreplanTM TPS in an inhomogenous home-made phantom.   Materials and Methods: Thermoluminescent dosimeter-100 (TLD-100) chips were used within inhomogeneous home-made phantom for dose measurement; CoreplanTM was also applied for dose calculation. Finally, difference between measured doses and calculated doses was gotten to calculate dosimetry accuracy of the TPS at PTV and neighbor's organ at risks region.   Results: Findings indicated that for regions near PTV, Coreplan TPS leads to an overdose estimation up to 2.3% and 4.8% for the 6 and 15 MV energies, respectively and in regions far from primary field, the Coreplan TPS underestimated the dose compared to the measurements which might be due to scattered radiation that is not well considered in the TPS.   Conclusion: Due to the inhomogeneous in the thorax region, the dose calculation accuracy of TPS should be appropriate. The agreement criterion was determined according to ICRU recommendation, which suggest the accuracy of ±5% in the delivery of an absorbed dose to a target volume. According to the results, it is concluded that the accuracy of dose calculation of Coreplan TPS showed good agreement with experimental data.
      کلید واژگان
      Radiotherapy
      Dose calculation accuracy
      Treatment Planning System
      TLD dosimeter

      شماره نشریه
      12
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Department of Biochemistry and Biophysics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran.
      Department of Biochemistry and Biophysics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran.

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2019.12996
      http://ijmp.mums.ac.ir/article_12996.html
      https://iranjournals.nlai.ir/handle/123456789/324629

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب