نمایش مختصر رکورد

dc.contributor.authorSalimi, Yazdanen_US
dc.contributor.authorDeevband, MohammadRezaen_US
dc.contributor.authorGhafarian, Pardisen_US
dc.date.accessioned1399-07-09T07:34:27Zfa_IR
dc.date.accessioned2020-09-30T07:34:27Z
dc.date.available1399-07-09T07:34:27Zfa_IR
dc.date.available2020-09-30T07:34:27Z
dc.date.issued2018-12-01en_US
dc.date.issued1397-09-10fa_IR
dc.date.submitted2018-05-21en_US
dc.date.submitted1397-02-31fa_IR
dc.identifier.citationSalimi, Yazdan, Deevband, MohammadReza, Ghafarian, Pardis. (2018). Assessment the effect of CT localizer parameter on radiation dose and image quality of GE CT spiral images, A phantom study. Iranian Journal of Medical Physics, 15(12), 323-323. doi: 10.22038/ijmp.2018.12977en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2018.12977
dc.identifier.urihttp://ijmp.mums.ac.ir/article_12977.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324610
dc.description.abstract<strong>Introduction</strong>: Using computed tomography (CT) is increasing significantly in Iran and worldwide. Reduction of CT's radiation dose is a critical concern. The aim of this study was evaluating the effect of localizer kVp on spiral CT images when the tube current modulation (TCM) is activated. <strong>Materials and Methods:</strong> A special wedding cake phantom with circular intersection and diameters of 15 to 40 cm was scanned on a GE VCT 64 slice scanner. The whole length of phantom (84cm) was scanned with kVps of 80,100,120 and 140. The image noise was measured in SD of Ct numbers and the radiation dose was measured in term of CTDIvol. The tube current variation through the Z-Axis was extracted from DICOM images. <strong>Results:</strong> Function of TCM was affected by changing the scout view parameters. By increasing the localizer kVp the average used tube current was decreased and image noise was increased (8-32%, p<0.05); especially for larger phantom diameters and wide kVp difference between localizer and spiral kVps (up to 32%). On the other hand, the localizer with lower kVp than spiral leads to higher CTDIVOLs and lower image noises. The image noise was closer to chosen Noise Index when the localizer and spiral scan were in the same kVps. <strong>Conclusion:</strong> The attenuation of localizer X-ray is the criteria of tube current changing in spiral CT. The attenuation is variable in different kVps of X-ray. The ability of TCM system was the best in offering the constant image noise when the localizer and spiral scans were in the same kVp. Inappropriate localizer kVp may increase the patients' radiation dose or degrade the image quality by miscalculations in TCM systemen_US
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2018.12977
dc.subjectComputed Tomography Tube Current Modulation Patient Doseen_US
dc.subjectkVpen_US
dc.titleAssessment the effect of CT localizer parameter on radiation dose and image quality of GE CT spiral images, A phantom studyen_US
dc.typeTexten_US
dc.typeConference Proceedingsen_US
dc.contributor.departmentDepartment of biomedical engineering and Medical Physics, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iranen_US
dc.contributor.departmentDepartment of biomedical engineering and Medical Physics, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iranen_US
dc.contributor.departmentChronic Respiratory Diseases Research Center, National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran. PET/CT and Cyclotron Center of Masih Daneshvari Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iranen_US
dc.citation.volume15
dc.citation.issue12
dc.citation.spage323
dc.citation.epage323


فایل‌های این مورد

فایل‌هااندازهقالبمشاهده

فایلی با این مورد مرتبط نشده است.

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد