• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Medical Physics
      • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Medical Physics
      • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.

      (ندگان)پدیدآور
      Sadeghi, SaeidehMahdavi, Seied rabiSaeedzadeh, ElhamSalmanian, SorayaEsmaili, Golbarg
      Thumbnail
      نوع مدرک
      Text
      Conference Proceedings
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction:   The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer.   Materials and Methods:   Two CT scan was performred for each patient. Once in inspiration and once in Expiration mode and the images fused together. GTV and CTV were contoured in two modes. The CTVs combined and by increasing the 10 millimetres margin, the PTV was made. An IMRT plan and a 3DCRT plan for each patient were performed. The plans comparison was based on dose- volume histogram. Organ at risk sparing, HI, CI were analysed.   Results: V20 of Lung (P=0.043) were lower in IMRT than the 3DCRT plans. The maximum dose of spinal cord (P=0.043) were lower in 3D-CRT than IMRT plans. HI (P=NS) and CI(P=NS) had no significant difference in 3D-CRT and IMRT plans. Conclusion: The IMRT technique, in addition to optimizing the dose distribution, reduces lung doses and prevents the occurrence of radiation pneumonia. Also, the method used in this study can be a substitute for 4DCT in treatment centers that are not equipped with this technique.
      کلید واژگان
      IMRT
      3D-CRT
      Inspiration
      expiration

      شماره نشریه
      12
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Msc Student of Medical Radiation Engineering. Islamic Azad University, Science and Research Branch. Tehran, Iran.
      Associate Professor of Medical physics. Medical physics Dept. Iran University of Medical Sciences. Tehran, Iran.
      Assistant Professor of Medical Radiation Engineering. Islamic Azad University, Science and Research Branch. Tehran, Iran.
      Assistant Professor of Radiation Oncology. Radiation Oncology Dept, Faulty of Medicine, Iran University of Medical Sciences. Tehran, Iran.
      Ph.D. of medical physics. Pars Hospital radiotherapy center. Tehran, Iran.

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2018.12951
      http://ijmp.mums.ac.ir/article_12951.html
      https://iranjournals.nlai.ir/handle/123456789/324593

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب