• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Medical Physics
      • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Medical Physics
      • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

      (ندگان)پدیدآور
      Esmaili Torshabi, AhmadDastyar, Seyyed Amirreza
      Thumbnail
      نوع مدرک
      Text
      Conference Proceedings
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are several methods to compensate the effect or tumor motion error, clinically. Recently, stereotactic body radiation therapy strategy has been proposed clinically that can lead to better local control using external surrogates. In this method, the exact information of tumor position in real-time is obtained using consistent correlation models between tumor motion and external surrogates motion. In this work, the influence of motion variability and the site of lung tumor has been taken into account over total treatment time.   Materials and Methods: In this study, motion information of lung tumor of real patients treated with the CyberKnife Synchrony system, have been utilized. Real time tumor motion tracking is performed by developing a fuzzy logic based correlation model to predict tumor position using external surrogate's motion. In this work the variabilities of lung tumor motion in the Superior-Inferior (SI), Latero-Lateral (LL), and Anterior-Posterior (AP) directions and their geometrical location in lung region have been investigated on the performance accuracy of correlation model, as metric. With divided lung tumors location into four upper, lower, left and right sites.   Results: Targeting errors between of 20 patients with lung tumors located at various sites have been recorded using Root Mean Square Error (RMSE). Intra-fraction variation of lung tumors ranges from 4.0 to 70.5 mm at SI, 1.7 to 75.5 mm at LL, 1.8 to 40.7 mm at AP directions. Total treatment time ranges between 27.0 to 118.8 minutes over total patients. Moreover, the average of RMSEs during tumor tracking by means of correlation model are 15.6 mm, 6.7 mm, 7.8 mm and 9.5 mm for upper, lower, left and right tumors, respectively in one division.   Conclusion: There are many influencing factors and patterns on lung tumor motion management at external radiotherapy. By understanding these factors and considering to them during real time tumor tracking, the treatment quality may have enhanced significantly at stereotactic body radiation therapy. In this work we assess tumors motion variability and their geometrical sites on the accuracy of our developed fuzzy correlation model, quantitatively.
      کلید واژگان
      Stereotactic Body Radiation Therapy
      Lung tumor motion
      Tumor site
      tumor variability

      شماره نشریه
      12
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Medical Radiation Division, Faculty of New Sciences and Technologies, Graduate University of Advanced Technology, Haftbagh St. Kerman, Iran
      Medical Radiation Division, Faculty of New Sciences and Technologies, Graduate University of Advanced Technology, Haftbagh St. Kerman, Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2018.12939
      http://ijmp.mums.ac.ir/article_12939.html
      https://iranjournals.nlai.ir/handle/123456789/324581

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب