• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 15, Special Issue-12th. Iranian Congress of Medical Physics
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Independent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader

    (ندگان)پدیدآور
    Kanani, AbolfazlKarbasi, SarehMosleh-Shirazi, Mohammad Amin
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and step size. Usually brachytherapy treatment planning systems do not apply a correction for transit time and the afterloader unit itself adjusts the final dwell times taking account of the transit time. The independent verification of transit time for each HDR afterloader is recommended before clinical use. Some published reports have used a video camera and/or stopwatch to perform this task. To the best of our knowledge, there is no published report of transit time measurement for the recently released BEBIG SagiNova® HDR afterloader unit. The goal of this study is to independently evaluate the corrected source transit time of this afterloader unit without using a video camera or stopwatch.   Materials and Methods: The assessed unit was a newly installed SagiNova® 60Co HDR afteroloader (software version 1.2.4; Eckert & Ziegler BEBIG GmbH). A dosimetric method was used. The measurements were performed using a previously commissioned PTW source check4п (type 33005) well- type ionization chamber and UNIDOS E® electrometer. A 30 cm plastic needle and a 100 cm transfer tube were used to accurately place the source at the point of maximum response (‘sweet spot') of the well chamber. Plans were generated using SagiPlan version 2.0 to irradiate the well chamber for dwell times of 3, 5, 10, 15, 20, 30, 40, 60, and 120 s. All the measurements were repeated three times. The transit time following its correction by the afterloader software were assessed using the ESTRO-recommended approach of obtaining transit time correction factors and another strategy established for teletherapy sources. The results obtained using the two strategies were also compared.   Results: For the measured setup, the transit time was 0.7 s using both methods. The mean ESTRO transit time correction factor was 0.93 (range 0.88 to 0.99 for dwell times of 3 to 120 s).   Conclusion:   This work demonstrates an accurate dosimetry-based method to measure source transit time during the commissioning step of HDR BT afteroloaders, using a practical approach and available standard equipment. It also shows the consistency of the results between the two dosimetric methods of obtaining source transit time. The results suggest that the afterloader software correction does not completely eliminate this effect, which results in slightly longer    irradiation times.
    کلید واژگان
    Brachytherapy
    High Dose Rate
    Transit time
    BEBIG
    SagiNova

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran Student research committee, Shiraz University of Medical Sciences, Shiraz, Iran
    Physics Unit, Department of Radiotherapy and Oncology, Shiraz University of Medical Sciences, Shiraz, Iran
    Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran Physics Unit, Department of Radiotherapy and Oncology, Shiraz University of Medical Sciences, Shiraz, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.12912
    http://ijmp.mums.ac.ir/article_12912.html
    https://iranjournals.nlai.ir/handle/123456789/324559

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب