      Influence of Compensator Thickness and Field Size on Buildup factor of a Brass Compensator for Intensity- Modulated Radiation Therapy

      (ندگان)پدیدآور
      Balvasi, ElnazHaghparast, AbbasHejazi, Peyman
      Thumbnail
      نوع مدرک
      Text
      Conference Proceedings
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as well as the subsequent calculations of dose distributions. The buildup factor, ‘B', is one of these important properties of a material to be used for compensator construction. It directly affects the dose quantity. Materials and Methods: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as well as the subsequent calculations of dose distributions. The buildup factor, ‘B', is one of these important properties of a material to be used for compensator construction. It directly affects the dose quantity. Results: Our results indicated that the compensator thickness and field size have the most significant effect on the calculation of buildup factor for the 6-MV photon beam. Conclusion: Influence of compensator thickness and field size on calculation buildup factor can reduce the error due to delivered dose to target volume and organs at risk
      کلید واژگان
      Intensity Modulated Radiation Therapy Compensator Buildup factor

      شماره نشریه
      12
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Master of Medical Physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran Email: e_balvasi.ph87@yahoo.com, Tel: +98 9169600536
      Doctor of Medical Physics, Department of Medical Physics, Kermanshah University of Medical Sciences, Kermanshah, Iran
      Doctor of Medical Physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2018.12642
      http://ijmp.mums.ac.ir/article_12642.html
      https://iranjournals.nlai.ir/handle/123456789/324441

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب