    Thyroid dose and dose reduction method from CT scan of head and neck

    (ندگان)پدیدآور
    Shahraki, FatemehSargazi, VidaBidari, ZohreOrdoni, Jalal
    Thumbnail
    نوع مدرک
    Text
    Conference Proceedings
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and in children, due to longer life expectancy than adults, cancer has a greater chance of developing and developing. Therefore, awareness of the amount of thyroid dose and dose reduction methods are essential. Results: According to the results, when performing CT scans of the head and neck, thyroid gland radiation is very high, but the use of optimization techniques leads to a decrease in the amount of thyroid receiving dose. Dose optimization is divided into three stage s: 1-Before scanning 2- During the scan, which includes: patient position, scan parameters, and shields inside and outside the field; 3- After scanning, which includes: rehabilitation filter and quality control. For example,  the  use  of  protective  shields  during  head  and  neck  CT tests leads to a reduction in the thyroid dose of approximately 40% to 60%. Conclusion: According to the principle of ALARA, the aim of applying optimization techniques is to reduce the amount of thyroid receiving dose while mainta ining image quality. The most effective  of  these  techniques  in  head  and  neck  CT  scans  is  the  use  of protective shield that minimizes the thyroid dose
    کلید واژگان
    CT scan absorb dose thyroid shielding dose reduction

    شماره نشریه
    12
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    B.S. student of radiology, Department of radiology, Faculty of Para medicine, zahedan University of Medical Sciences, zahedan.
    M.S of medical physic., Department of radiology, Faculty of Para medicine, zahedan University of Medical Sciences, zahedan. Email: vida.sargazi8@gmail.com
    B.S. student of radiology, Department of radiology, Faculty of Para medicine, zahedan University of Medical Sciences, zahedan.
    M.S of radiobiology., Department of radiology, Faculty of Para medicine, zahedan University of Medical Sciences, zahedan. Email jalalordoni@gmail.com

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.12365
    http://ijmp.mums.ac.ir/article_12365.html
    https://iranjournals.nlai.ir/handle/123456789/324380

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب