      The study of dose gamma rays of 192Ir source on DNA single strand break (SSB) and DNA double strand break (DSB) in soft tissue phantom

      (ندگان)پدیدآور
      Naderi, NadereTavakoli-Anbaran, Hossein
      Thumbnail
      نوع مدرک
      Text
      Conference Proceedings
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: Passage of ionizing radiation through the organs of living creatures develops clusters of damaged nucleotides inside the DNA rounds. 192Ir Gamma source is one of the most widely used sources in brachytherapy of cervical and prostate cancer. Thus, in this research, we investigated the flux of photons and its resulting secondary electrons, the single-strand break (SSB) and double-strand break (DSB) that these electrons develop in the molecule DNA, and the dose rate in dimensions of DNA at different distances off the source in a soft tissue spherical phantom. Materials and Methods: In this research, using Code MCNPX, we defined a soft tissue spherical phantom, where iridium 192Ir gamma source was placed in its center with 13 spherical cells with a radius of 30μm at distances off the mean free path multiplier of the average energy of this source. In the center of each of the 13 cells, cylinders with a radius of 100nm and height of 300nm were considered as approximate dimensions of the molecule DNA. Next, using this code, we calculated the flux and dose inside the cylinders. Furthermore, through the obtained electron flux, we obtained the efficiency of DNA single-strand break and double-strand break using Monte Carlo Damage Simulation (MCDS) Code. Results: The data indicated that as the distance from the source increased, the flux of photons and electrons decreased due to interaction with the environment. Thus, the dose rate values for this source with the assumptive activity of 1mci inside the cylinders with dimensions of DNA at distances of 0.04, 0.046, 0.052, 0.058, 0.064, 0.07, 0.076, 0.1, 0.5, 1, 1.5, 2, 2.5 cm (the cells lie within these distances) were 7.56, 5.66, 4.36, 3.39, 2.65, 2.06, 1.63, 0.85, 2.8×10-2, 7.35×10-3, 3.58×10-3, 2.06×10-3, 1.41×10-3  μGy/s, respectively. Furthermore, the probability of single-strand break(SSB) and double-strand break(DSB) also decrease due to lower flux of electrons at farther distances. It had the maximum probability in 2.5cm of 0.2% and 0.009% in single-strand and double-strand damages, respectively. Conclusion: The results suggested that in addition to the interaction between rays and the environment and occurrence of photoelectric, Campton, and pair production, the energy of the source photons decreased, and secondary electrons were generated. Electrons are the main cause of development of break in the molecule DNA. In this regard, as the data indicated, at the farthest distance, electron flux still existed in the cylinders with dimensions of DNA, causing damage. Thus, investigation of the breaks of strand DNA and the dose resulting from the 192Ir source is important and should be taken into account in brachytherapy in order to prevent its delayed effect after the treatment.
      کلید واژگان
      MCNPX Code
      MCDS Code
      Double-Strandbreak (DSB)
      Single-Strand Break (SSB)
      Dosimetry

      شماره نشریه
      12
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Masters student, Faculty of Physics and Nuclear Enginering, Shahrood University of Technology , Shahrood, Iran
      Facultu of Physics- University of Sahrood- Shahrood- Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2018.11953
      http://ijmp.mums.ac.ir/article_11953.html
      https://iranjournals.nlai.ir/handle/123456789/324345

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب